CITB Heating and Plumbing Services: Core: general safety practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

16 of our 200 CITB HS&E Specialist Test: Heating and Plumbing Services (CITB-SPEC-HAPS) questions are on core: general safety, about 8% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. On a heating and plumbing job, which of these is a common electrical fire risk on site?

Show answer

Answer: D. Using twin and earth as an extension lead

  • Common faults include flat twin and earth cable used as an extension lead.
  • Others are overloaded sockets, daisy-chained leads and coiled leads not unwound.

Installations must be designed and maintained by competent people.

Why the others are wrong:

A: supporting cables helps prevent damage.

B: RCDs reduce the risk of fire and shock.

C: 110 V supplies reduce risk; they are not a fire fault.

Memory trick:

Twin and earth is for walls, not leads.

Find it in the book

HSE HSG168 (3rd edition, 2022), page 27

Reg HSE HSG168 (3rd edition, 2022), paragraph 134

Q2. Where should LPG cylinders for site heaters be stored when not in use?

Show answer

Answer: C. Outdoors in a secure, ventilated cage

  • LPG cylinders should be stored outdoors in a secure cage.
  • Storage areas should be well ventilated and away from ignition sources.

Keep flammable gases apart from other flammable materials.

Why the others are wrong:

A: flammable gases must be kept apart from oxygen.

B: LPG is heavier than air and collects in low spaces.

D: LPG must not be stored inside site cabins.

Memory trick:

LPG lives outside.

Find it in the book

HSE HSG168 (3rd edition, 2022), page 16

Reg HSE HSG168 (3rd edition, 2022), examples of ways to reduce the risks caused by potential sources of fuel

Q3. An electrician wants to run the temporary distribution board along the main escape corridor. What does fire guidance say?

Show answer

Answer: D. Only if a robust risk assessment justifies it

  • Do not put temporary distribution equipment in escape routes unless justified by a robust risk assessment.
  • Ad hoc additions by people who are not competent must not be allowed.

Escape routes must stay usable in a fire.

Why the others are wrong:

A: escape routes should be kept clear of such equipment.

B: job length does not remove the rule.

C: locking it does not deal with the escape route risk.

Memory trick:

Keep the way out clear.

Find it in the book

HSE HSG168 (3rd edition, 2022), page 27

Reg HSE HSG168 (3rd edition, 2022), paragraph 133

Q4. You are using a drum-type extension lead to run a heat gun. What should you do?

Show answer

Answer: A. Unwind it fully before use

  • Using coiled extension leads without unwinding them fully is a common fire risk.
  • So is plugging extension leads into each other.

Leads should be supported and protected from damage.

Why the others are wrong:

B: plugging leads into each other is a listed fault.

C: coiled leads can overheat when under load.

D: covering it can trap heat.

Memory trick:

Unroll before you load.

Find it in the book

HSE HSG168 (3rd edition, 2022), page 27

Reg HSE HSG168 (3rd edition, 2022), paragraph 134

Q5. Your transformer lead has a split outer sheath. What should you do?

Show answer

Answer: A. Take it out of use and label it DO NOT USE

  • Suspect or faulty equipment must be taken out of use, labelled DO NOT USE and kept secure.
  • It stays out of use until examined by a competent person.

Damaged cable sections should be replaced completely.

Why the others are wrong:

B: damaged equipment must be taken out of use straight away.

C: taping over damage is not a safe repair.

D: that passes the danger to someone else.

Memory trick:

Damaged? Tag it and bag it.

Find it in the book

HSE INDG231 (rev1, 2012), page 4

Reg HSE INDG231 (rev1, 2012), work safely

Q6. What is the maximum tripping current of an RCD used to protect people?

Show answer

Answer: A. 30 mA

  • RCDs for protecting people have a rated tripping current of not more than 30 mA.
  • Use the test button regularly.

An RCD detects some, not all, faults.

Why the others are wrong:

B: 13 A is a fuse rating, not an RCD sensitivity.

C: 100 mA is too high for personal protection.

D: 300 mA is too high for personal protection.

Memory trick:

Thirty milliamps saves lives.

Find it in the book

HSE INDG231 (rev1, 2012), page 3

Reg HSE INDG231 (rev1, 2012), provide a safety device

Want 194 more CITB Heating and Plumbing Services questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.