Part J Mock Test: Combustion Appliances, Flues and Hearths

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

Part J is the part of the Building Regulations that covers fitting boilers, stoves, fires and their flues safely: air supply, flues and chimneys, terminal positions, hearths, carbon monoxide alarms and fuel storage. It comes up on gas, OFTEC oil and HETAS solid fuel courses, and in building control checks on your work.

These timed mocks are written from Approved Document J (2010 edition with the 2022 amendments). You get 90 questions across 3 mocks, each with a full explanation and the paragraph it comes from. The first mock is free.

Mock exams

PART-J-FLUES

Part J Combustion Appliances and Flues

30 questions · 45 minutes · 70% to pass

Set by your centre. Approved Document J is the key reference.

Find it in the book: Every answer shows the page where you can find it in Approved Document J (2010 incl. 2022 amendments).

Practise in the real exam format

Take timed papers, flag questions to revisit, and review every answer after submitting. Mock 1 is free.

About the Part J Flues exam

  • Approved Document J gives specific guidance for solid fuel, gas (up to 70 kW net input) and oil (up to 45 kW output) installations, plus flues and fuel storage
  • Tested as part of gas, OFTEC oil and HETAS solid fuel courses, and needed for building control sign-off
  • Topics: general provisions, air supply and CO alarms; flues, chimneys and terminals; hearths, fireplaces, fuel storage and appliance rules
  • Our practice format is 30 questions in 45 minutes, 70% to pass
  • Written from Approved Document J, 2010 edition incorporating the 2010, 2013 and 2022 amendments
  • Every answer has a full explanation, including the working on air vent and flue sizing

How the online Part J Flues mock exam works

Each mock works like an online exam simulator for the Part J Flues: the same number of questions and time limit as the real exam, flags for questions to revisit, then your score and a worked answer for every question.

Questions per mock30
Time limit45 minutes
Pass mark70%
BooksSet by your centre. Approved Document J is the key reference.
Mock exams3 (1 free)

Part J Flues: frequently asked questions

What does Part J of the Building Regulations cover?

Combustion appliances and fuel storage: getting enough air to appliances, discharging the products of combustion safely through flues and chimneys, protecting the building from fire and heat with hearths and shielding, carbon monoxide alarms, and storing oil and LPG safely.

When do I need a carbon monoxide alarm under Part J?

Approved Document J (with the 2022 amendments) expects a CO alarm in the room whenever a new or replacement fixed solid fuel, gas or oil appliance is installed in a dwelling. Gas appliances used only for cooking are excluded. Our mocks test the details, including where the alarm goes.

Is there a Part J exam?

Not as one standalone exam. Part J questions come up within gas (ACS), OFTEC oil and HETAS solid fuel courses and assessments. These mocks let you practise that part on its own.

Are these official questions?

No. Every question is original, written by FreeMocks from Approved Document J. We're independent and not affiliated with Gas Safe, OFTEC, HETAS or any course provider.