Part J Flues: General provisions, air supply and CO alarms practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

33 of our 90 Part J Combustion Appliances and Flues (PART-J-FLUES) questions are on general provisions, air supply and co alarms, about 37% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. Requirements J1 (air supply) and J2 (discharge of products of combustion) are limited to which appliances?

Show answer

Answer: C. Fixed combustion appliances, including incinerators

  • J1 and J2 apply only to fixed combustion appliances (including incinerators).
  • J3 is further limited to fixed appliances in dwellings.

Portable appliances fall outside Part J.

Why the others are wrong:

A: J1 and J2 apply only to fixed appliances.

B: the dwelling limit belongs to J3, not J1 and J2.

D: 70kW net is the scope of Section 3 guidance, not a limit on J1 and J2.

Memory trick:

J1 and J2: fixed kit, any building.

Find it in the book

Approved Document J (2010 incl. 2022 amendments), page 9

Reg Approved Document J (2010 incl. 2022 amendments), Requirements J1 and J2, Limits on application

Q2. A non-proprietary air vent is made by combining an airbrick, a sleeve and an internal grille. What equivalent area should the assembly be taken to have?

Show answer

Answer: A. That of the component with the smallest equivalent area

  • For an assembly of two or more components, take the equivalent area of the component with the smallest equivalent area.
  • Keep the assembly simple and smooth.

For a single proprietary unit, use the maker's declared equivalent area.

Why the others are wrong:

B: the parts are in series, so the smallest one governs.

C: an average overstates the flow through the tightest component.

D: the outside face may not be the restriction; the smallest component governs.

Memory trick:

A vent is only as big as its tightest part.

Find it in the book

Approved Document J (2010 incl. 2022 amendments), page 19

Reg Approved Document J (2010 incl. 2022 amendments), para 1.13

Q3. Where does Approved Document J say an air vent should not be located, except on the basis of specialist advice?

Show answer

Answer: B. Within a fireplace recess

  • Air vents should not be located within a fireplace recess except on specialist advice.
  • Vents should not be made in fire-resisting walls other than external walls.

Vents in a recess can stir ash and upset the fire.

Why the others are wrong:

A: external walls are the normal place for vents to outside.

C: floor vents near appliances are suggested as a way to avoid draughts.

D: high external vents are suggested for good mixing of cold air.

Memory trick:

No vents in the recess.

Find it in the book

Approved Document J (2010 incl. 2022 amendments), page 19

Reg Approved Document J (2010 incl. 2022 amendments), para 1.10

Q4. In which of these cases does Approved Document J expect a notice plate to be provided?

Show answer

Answer: C. Where a flue is provided during refurbishment work, such as relining a chimney

  • A notice plate is needed where a hearth, fireplace (including a flue box), flue or chimney is provided or extended.
  • This includes a flue provided as part of refurbishment work.

This is the usual way of meeting requirement J5.

Why the others are wrong:

A: the plate is also expected when a flue is provided during refurbishment.

B: the trigger is providing or extending a hearth, fireplace, flue or chimney, for any fuel.

D: oil tank labels are a separate pollution notice under J7.

Memory trick:

New or extended flue, new plate.

Find it in the book

Approved Document J (2010 incl. 2022 amendments), page 28

Reg Approved Document J (2010 incl. 2022 amendments), para 1.57

Q5. A householder's chimney is to be relined with a new flexible flue liner, with no change of appliance. How does Approved Document J treat this work?

Show answer

Answer: D. It is building work and must be notified

  • Flues are controlled services; providing a new or replacement flue liner is building work.
  • Examples: inserting new rigid or flexible linings, or a cast in situ liner that significantly alters the flue size.

If in doubt, the local authority or an approved inspector can advise.

Why the others are wrong:

A: providing a new or replacement liner is building work, not a simple repair.

B: the trigger is the new liner, not rebuilding the stack.

C: AD J gives no size-based exemption for relining with new linings.

Memory trick:

New liner, new notification.

Find it in the book

Approved Document J (2010 incl. 2022 amendments), pages 23 to 24

Reg Approved Document J (2010 incl. 2022 amendments), para 1.35

Q6. A carbon monoxide alarm for a new stove is to be mounted on a wall rather than the ceiling. Where should it go?

Show answer

Answer: D. As high as possible, above doors and windows, but not within 150mm of the ceiling

  • Wall-mounted: as high as possible, above any doors and windows, but not within 150mm of the ceiling.
  • Ceiling-mounted: at least 300mm from any wall.
  • Either way, 1m to 3m horizontally from the appliance.

Further detail is in BS EN 50292.

Why the others are wrong:

A: AD J asks for the alarm to be as high up as possible, not at head height.

B: the top 150mm is the zone to avoid.

C: AD J gives a high-level position, not a low one.

Memory trick:

High on the wall, but leave 150 to the ceiling.

Find it in the book

Approved Document J (2010 incl. 2022 amendments), page 41

Reg Approved Document J (2010 incl. 2022 amendments), para 2.36(a)

Want 84 more Part J Flues questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.