Gas Safety (Installation and Use) Regulations 1998: the key rules

Updated 30 October 2026. Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

The Gas Safety (Installation and Use) Regulations 1998 set out how gas fittings, appliances and flues must be installed, maintained and used in Great Britain. The parts that matter most are Regulation 3 (only competent people, and businesses in the HSE-approved class, which is Gas Safe Register, may do gas work), Regulation 26 (appliance safety checks), Regulation 30 (room-sealed appliances in bathrooms and bedrooms), Regulation 36 (annual landlord checks) and Regulation 37 (what to do about a gas escape). These are core topics in ACS assessments such as CCN1.

Who the regulations apply to

The regulations cover gas fittings in homes and many other premises in Great Britain. They place duties on installers, on employers and self-employed people, on landlords and on anyone responsible for premises where an appliance is used. Northern Ireland has its own version, the Gas Safety (Installation and Use) Regulations (Northern Ireland) 2004. HSE publishes an Approved Code of Practice and guidance, L56 (5th edition, 2018), that explains how to comply.

PartRegulationsCovers
A1 to 2General: citation and interpretation
B3 to 10Gas fittings, general provisions: competence, materials, general safety precautions, electrical continuity
C11 to 17Meters and regulators
D18 to 24Installation pipework: safe use, testing and purging, marking
E25 to 34Gas appliances: safety precautions, flues, room-sealed rules, testing, use of dangerous appliances
F35 to 36AMaintenance: duties of employers, the self-employed and landlords (36A added in 2018)
G37 to 41Miscellaneous: gas escapes, exemptions and revocations

Regulation 3: competence and Gas Safe registration

Regulation 3(1) says nobody may work on a gas fitting or gas storage vessel unless they are competent to do so. Regulation 3(3) goes further for businesses. An employer, or a self-employed person, may only carry out work on gas fittings, or let their employees do so, if they belong to a class of persons approved by HSE. At present that is the Gas Safe Register. The regulation does not name Gas Safe directly, which is a detail exam questions sometimes test.

In practice, competence is shown by holding the right ACS certificates for the work and appliances involved. CCN1, the core domestic gas safety assessment, and its appliance assessments must be renewed every five years to stay on the Gas Safe Register.

Regulations 6, 10 and 22: working safely on pipework

Several Part B and Part D regulations describe what you must do whenever you work on gas pipework. These are the ones most often asked about.

  • Regulation 6: general safety precautions. If you leave a fitting unattended, every incomplete gasway must be sealed with the appropriate fitting or the fitting must otherwise be safe (6(2)). When you disconnect a fitting, seal off every outlet of every pipe it was connected to with the appropriate fitting (6(3))
  • Regulation 10: where it is needed to prevent danger, fit a suitable bond to maintain electrical continuity until the work is finished, then restore continuity permanently
  • Regulation 22: after any work that could affect gas tightness, test the pipework for tightness, then purge it. Seal any unused outlet with the appropriate fitting and retest any connection loosened for purging

Regulation 26: the checks after working on an appliance

Regulation 26(1) says nobody may install an appliance unless it can be used without danger. Regulation 26(9) lists the things you must examine straight after any work on an appliance. They form the core of every gas safety check, and Regulation 36(9) requires landlord checks to cover them too. Any defect found must be reported to the responsible person and, if different, the owner.

  • (a) the effectiveness of any flue
  • (b) the supply of combustion air
  • (c) the operating pressure or heat input, or where neither can reasonably be checked, the combustion performance
  • (d) the operation of the appliance, to make sure it functions safely

Regulation 30: bathrooms and bedrooms

Regulation 30 controls which appliances can go in rooms where carbon monoxide is most dangerous. Regulation 30(4) extends the rules to cupboards and compartments inside those rooms, and to a cupboard or space next to the room that has an air vent into it.

RoomApplianceRule
Bathroom or shower roomAny gas applianceMust be room-sealed (30(1))
Room used for sleepingGas fire, other space heater or water heater over 14 kW gross heat inputMust be room-sealed (30(2))
Room used for sleepingGas fire, other space heater or water heater 14 kW gross or less, or any instantaneous water heaterMust be room-sealed or fitted with a safety control that shuts it down before combustion products build up to a dangerous level (30(3))

Regulations 33 and 34: testing and dangerous appliances

When you install an appliance with gas available, Regulation 33 requires you to test the connection for gas tightness straight away. You must also check the appliance was installed in line with the regulations, check the operating pressure against the manufacturer's figure, check the installation follows the manufacturer's instructions, and check that all gas safety controls work. If something is wrong, adjust it or disconnect and seal it.

Regulation 34(1) says the responsible person must not use, or allow the use of, an appliance they know or suspect is dangerous. Under 34(3), anyone working on gas fittings who finds an appliance they know or suspect is dangerous must take all reasonably practicable steps to tell the responsible person and, if different, the owner. The Gas Industry Unsafe Situations Procedure (IGEM/G/11) explains how to classify and deal with what you find, for example as immediately dangerous or at risk.

Regulation 36: landlord gas safety checks

Landlords of rented homes must keep gas fittings and flues they provide in a safe condition. Every appliance and flue must be checked by someone from the HSE-approved class, which in practice means a Gas Safe registered engineer, within 12 months of installation and then at least every 12 months. Regulation 36A, added in 2018, treats a check done in the two months before the deadline as if it was done on the deadline, so the original anniversary date is kept, much like an MOT.

  • Check each appliance and flue within 12 months of installation, then at intervals of no more than 12 months (36(3)(a))
  • Keep the record until two further checks have been done, or for 2 years if the appliance or flue has been removed (36(3)(c))
  • Give existing tenants a copy within 28 days of the check (36(6)(a))
  • Give new tenants a copy before they move in. Where the right to occupy is 28 days or less, the record can be displayed prominently instead (36(6)(b))
  • The record must include the date, address, landlord details, each appliance or flue and its location, any defects, remedial action, and the engineer's name, signature and registration number
  • Appliances the tenant is entitled to remove are not the landlord's responsibility

Regulation 37: gas escapes

If the responsible person knows or suspects gas is escaping, Regulation 37 says they must immediately take all reasonable steps to shut off the supply. If gas keeps escaping after that, or the smell persists, they must notify the gas supplier or emergency service at once. The gas supplier then has 12 hours from being told to stop the escape. Once the escape is stopped, gas must not be turned back on until steps have been taken to stop it happening again. The national gas emergency number in Great Britain is 0800 111 999.

Official sources

Practise for it

Test yourself with a free timed mock, with every answer explained.

Start a free mock

Frequently asked questions

How often does a landlord need a gas safety check?

At least every 12 months under Regulation 36(3). Under Regulation 36A, a check done in the two months before the deadline keeps the original anniversary date. Existing tenants must get a copy within 28 days of the check.

Which regulation requires Gas Safe registration?

Regulation 3(3). It says employers and the self-employed must be members of a class of persons approved by HSE. The Gas Safe Register is currently that approved class.

Can you fit an open-flued boiler in a bathroom?

No. Regulation 30(1) says any gas appliance installed in a room containing a bath or shower must be room-sealed.

What does Regulation 26(9) require you to check?

After working on an appliance, you must examine the effectiveness of any flue, the supply of combustion air, the operating pressure or heat input (or combustion performance where those cannot reasonably be checked), and the appliance's operation to make sure it is safe.

How long does a gas supplier have to stop an escape?

12 hours from being notified, under Regulation 37. The responsible person must take all reasonable steps to shut off the supply immediately if they suspect an escape.

Is the ACS CCN1 assessment based on these regulations?

Yes. CCN1 tests your knowledge of the Gas Safety (Installation and Use) Regulations alongside the relevant standards and IGEM procedures such as the Gas Industry Unsafe Situations Procedure. See our gas courses page for ACS preparation.

Related

Sources: Gas Safety (Installation and Use) Regulations 1998, as made (legislation.gov.uk); Part B, Regulations 3 to 10 (legislation.gov.uk); Part F as amended, including Regulation 36A (legislation.gov.uk); HSE L56: Gas Safety (Installation and Use) Regulations 1998, Approved Code of Practice and guidance; HSE: Domestic gas frequently asked questions. This guide paraphrases the rules for revision; always work from the current official documents.