43 of our 270 ACS CCN1 Core Domestic Gas Safety (ACS-CCN1) questions are on legislation, emergencies, unsafe situations and records, about 16% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. A landlord's last check was 1 January 2025. To suit a new tenancy, the next check is done on 1 August 2025. When is the next check now due?

Show answer

Answer: C. By 1 August 2026

  • 1 January to 1 August is 7 months, which is less than 10 months.
  • This resets the clock: the new deadline is 12 months from the latest check.
  • So the next check is due by 1 August 2026.

Only checks in the 10 to 12 month window keep the old date.

Why the others are wrong:

A: the preserved deadline is lost when the check is under 10 months.

B: a check less than 10 months after the last resets the clock.

D: the new deadline is 12 months from the latest check, not 14.

The maths

Previous check: 1 January 2025.
New check: 1 August 2025 = 7 months later (< 10 months).
Clock resets: deadline = 1 August 2025 + 12 months = 1 August 2026.

Memory trick:

Under 10 months: new start date.

Find it in the book

CORGI GID1, 10th Edition, Volume 2, page 195

Reg GSIUR Reg 36; GID1 Part 17

Q2. Which piece of legislation gave domestic gas users the freedom to buy gas from whichever supplier they wish, from April 1996?

Show answer

Answer: C. The Gas Act 1995

  • The Gas Act 1995 updated the Gas Act 1986 and licensed Gas Transporters.
  • From 1 April 1996 users, including domestic users, could buy gas from any supplier.
  • It also provides for safety regulations such as GSIUR and Rights of Entry.

Supplier choice came from the Gas Act, not from the safety regulations.

Why the others are wrong:

A: HSWA sets general workplace safety duties, not gas market competition.

B: these deal with safety cases and emergency services, not supplier choice.

D: these give the GT access to make dangerous situations safe.

Memory trick:

1995 Act, '96 choice.

Find it in the book

CORGI GID1, 10th Edition, Volume 1, page 9

Reg Gas Act 1995; GID1 Part 1

Q3. A domestic open-flued appliance terminates on a wall-adjacent position. Under the current GIUSP, how is this classified?

Show answer

Answer: D. At Risk

  • The procedure re-classified domestic wall-faced and wall-adjacent open-flued terminations to AR.
  • These offer an unacceptable risk to safe flue operation.

See Part 13 for termination positions.

Why the others are wrong:

A: the position itself is an unacceptable risk to safe flue operation.

B: the procedure re-classified these positions to AR.

C: NCS has been removed.

Memory trick:

Open flue hugging a wall: At Risk.

Find it in the book

CORGI GID1, 10th Edition, Volume 1, page 189

Reg IGEM/G/11; Part 13; GID1 Part 8

Q4. During an LGSR you find a CO alarm. How long is a typical service life?

Show answer

Answer: B. 5 to 10 years

  • CO alarms should comply with BS EN 50291.
  • Typical service life is 5 to 10 years, shown in the instructions and usually on the alarm.
  • Test using the test button.
  • If none is present or it is faulty/out of date, advise the landlord and tenant to fit one.

CO alarm checks are good practice, not a GSIUR requirement.

Why the others are wrong:

A: CO alarms last much longer than this.

C: this is longer than the typical range given.

D: alarms have a set service life whatever the test result.

Memory trick:

CO alarm: 5 to 10, then replace.

Find it in the book

CORGI GID1, 10th Edition, Volume 2, page 200

Reg BS EN 50291; GID1 Part 17

Q5. Your business subcontracts a landlord's check to another registered business. Whose registration number must the record show?

Show answer

Answer: D. The business that actually carried out the work

  • If work is subcontracted to another registered business, the record must show the registration number of the business who actually carried out the work.
  • Where two operatives share a large job, one takes overall responsibility or each issues their own record.

The record must trace back to who did the checks.

Why the others are wrong:

A: the requirement is the number of the business doing the work.

B: the record must show who did the work.

C: agents are not registered gas businesses.

Memory trick:

Who did it, signs it.

Find it in the book

CORGI GID1, 10th Edition, Volume 2, page 201

Reg GID1 Part 17

Q6. You find a house extension built over the PE gas service pipe. It is At Risk, but turning off the gas would not reduce the risk. What do you do?

Show answer

Answer: B. Warning notice naming who to contact, but no DDNU label

Where turning off will not remove the risk (e.g. built-over PE service, wrongly sited LPG bulk tank):

  • Explain why it is AR and why turning off will not help.
  • Do NOT attach a 'Danger Do Not Use' label.
  • Complete a warning notice stressing who to contact for further investigation, and get it signed.
  • If the user is not the owner, inform the owner in writing.

The matter goes to a responsible person or organisation for resolution.

Why the others are wrong:

A: turning off will not remove the risk, and no DDNU label is required.

C: it is AR, and Rights of Entry do not apply to AR.

D: a warning notice must be completed.

Memory trick:

Can't fix by switching off? Notice yes, label no.