ACS CCN1: Chimneys and flue testing practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

42 of our 270 ACS CCN1 Core Domestic Gas Safety (ACS-CCN1) questions are on chimneys and flue testing, about 16% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. To help an open-flue perform correctly, how far should it rise vertically above the draught diverter?

Show answer

Answer: D. At least 600mm

  • The flue should rise vertically for at least 600mm above the draught diverter
  • Take the most direct route and keep bends to a minimum
  • Avoid horizontal or slightly inclined runs

An initial vertical section gets the hot gases moving before any bend adds resistance.

Why the others are wrong:

A: 1.5m is not the stated figure; 600mm of vertical rise is recommended.

B: 150mm is far too short to establish a good flue draught.

C: 300mm is not enough; the guidance asks for 600mm of vertical rise.

Memory trick:

Up 600 before you turn.

Find it in the book

CORGI GID1, 10th Edition, Volume 2, page 57

Reg GID1 Part 13, Chimney system design

Q2. Two fanned-draught room-sealed terminals face each other across a side passage. What is the minimum distance between them?

Show answer

Answer: B. 1200mm

  • Dimension K, terminal facing a terminal: natural draught 600mm, fanned draught 1200mm
  • Dimension Y, terminal facing an opening into a building: 2000mm

Fanned terminals push products further, so they need more space between them.

Why the others are wrong:

A: 600mm is the natural-draught figure for a terminal facing a terminal.

C: 300mm is far too close for two fanned terminals blowing at each other.

D: 2000mm is for a terminal facing an opening into a building.

Memory trick:

Fans facing: 1.2m apart.

Find it in the book

CORGI GID1, 10th Edition, Volume 2, page 88

Reg GID1 Part 13, Table 13.13

Q3. You have lined a masonry chimney with a 125mm flexible liner for a gas fire. What does the guidance say about fitting a terminal?

Show answer

Answer: C. A terminal is needed, as the flue is 170mm or less across

  • Fit a terminal to any flue with a cross-sectional dimension of 170mm or less
  • Larger solid-fuel chimneys with a pot need no extra terminal unless nesting is a problem

A 125mm liner is well under 170mm, so a suitable gas flue terminal must be fitted.

Why the others are wrong:

A: terracotta chimney inserts are not suitable for use with gas appliances.

B: the pot exemption only applies to flues larger than 170mm built for solid fuel.

D: the nesting rule is for large flues over 170mm; a 125mm flue always needs one.

Memory trick:

170 or under? Put a terminal on it.

Find it in the book

CORGI GID1, 10th Edition, Volume 2, page 45

Reg GID1 Part 13, Flue terminal

Q4. An open-flued boiler has a 100mm spigot and 100mm flue with two 135° bends and a 100mm GC1 terminal. Vertical height Ha is 2.0m and total flue length 2.4m. Using Ki = Ko = 2.5, Ke = 0.78/m, 0.61 per bend and 0.60 for the terminal, what is the equivalent height and the verdict?

Show answer

Answer: C. About 1.40m, so likely to be satisfactory

  • He = Ha x (Ki + Ko) / [(Ki + Ko) - (Ke x Ha) + Sum K]
  • Sum K here is 3.692, giving He of about 1.40m
  • Table 13.4 requires 1.0m for appliances other than gas fires

The flue exceeds the minimum, so it is likely to work, but it must still pass the flue flow and spillage tests.

Why the others are wrong:

A: this comes from leaving out the (Ke x Ha) term in the denominator.

B: 0.86m is the book's worked example with a ridge terminal and different dimensions, not this flue.

D: this comes from leaving the flue run resistance out of the sum of K.

The maths

Step 1: sum the other resistances.
Two 135° bends = 2 x 0.61 = 1.22
GC1 terminal = 0.60
Flue run = 2.4 x 0.78 = 1.872
Sum K = 1.22 + 0.60 + 1.872 = 3.692

Step 2: denominator = (Ki + Ko) - (Ke x Ha) + Sum K
= 5.0 - (0.78 x 2.0) + 3.692 = 5.0 - 1.56 + 3.692 = 7.132

Step 3: He = Ha x (Ki + Ko) / denominator = 2.0 x 5.0 / 7.132 = 1.40m

Step 4: Table 13.4 needs 1.0m for 'other appliances'. 1.40m exceeds this, so the flue is likely to be satisfactory.

Memory trick:

Bigger He than the table = likely OK, but always smoke test anyway.

Find it in the book

CORGI GID1, 10th Edition, Volume 2, page 58

Reg GID1 Part 13, Equivalent flue height, Tables 13.2 to 13.4

Q5. A fanned-draught room-sealed terminal is to be sited inside a carport. Which requirements apply?

Show answer

Answer: B. Two open sides, and 200mm from roof to terminal top

  • The carport or extension needs at least two completely open, unobstructed sides
  • Lowest part of roof to top of terminal: 600mm natural draught, 200mm fanned draught
  • A covered passageway is not a carport

Open sides let the products disperse instead of collecting under the roof.

Why the others are wrong:

A: a carport must have at least two completely open, unobstructed sides.

C: 600mm is the figure for natural-draught appliances.

D: neither figure is the requirement.

Memory trick:

Carport: 2 open sides, fan 200, natural 600.

Find it in the book

CORGI GID1, 10th Edition, Volume 2, page 86

Reg GID1 Part 13, Carport or building extension

Q6. A customer asks you to fit a terracotta rain cap insert to the chimney serving their gas fire. Is this acceptable?

Show answer

Answer: A. No, terracotta inserts are not suitable for gas

  • Terracotta chimney inserts (rain caps) are not suitable for gas appliances
  • Use a gas flue terminal to a recognised standard instead

A rain cap can restrict the outlet and upset clearance of the products of combustion.

Why the others are wrong:

B: the fixing method does not matter; the insert type itself is unsuitable for gas.

C: flue size does not make a terracotta insert acceptable for gas appliances.

D: the guidance makes no such split; these inserts are unsuitable for any gas appliance.

Memory trick:

Rain caps keep rain out and gas fumes in.

Find it in the book

CORGI GID1, 10th Edition, Volume 2, page 45