ACS CCN1: Burner pressures, gas rates and safety devices practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

36 of our 270 ACS CCN1 Core Domestic Gas Safety (ACS-CCN1) questions are on burner pressures, gas rates and safety devices, about 13% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. When purging an NG installation with a total installation volume greater than 0.02 m3, how should the gas be released?

Show answer

Answer: B. Ignite it as soon as possible at a suitable appliance

  • Below 0.02 m3: you may purge through an appropriate fitting
  • Above 0.02 m3 (or LPG with low level risk): ignite the gas as soon as possible at a suitable appliance, such as a cooker
  • No suitable appliance? Connect a temporary burner

First remove ignition sources, turn appliances off and open doors and windows.

Why the others are wrong:

A: venting at a fitting is only acceptable where the installation volume is less than 0.02 m3.

C: the purge point is the point furthest from the meter, not the meter.

D: the purge is done at one point at a time, starting with the furthest from the meter.

Memory trick:

Over 0.02: burn it, don't dump it.

Find it in the book

CORGI GID1, 10th Edition, Volume 2, page 148

Reg GID1 Part 15, purging procedure

Q2. On a U6 meter the 1 ft3 test dial takes 60 seconds to complete one revolution with only the boiler running. Using a CV of 1040 Btu/ft3 and 3412 Btu per kW, what is the gross heat input?

Show answer

Answer: B. 18.29 kW

  • Btu/h = 3600 x 1040 / 60 = 62,400 Btu/h
  • kW = 62,400 / 3412 = 18.29 kW (gross)

On an imperial meter you time one full revolution of the test dial, which normally represents 1 ft3.

Why the others are wrong:

A: that is the result for a slower dial of 63 seconds, not 60.

C: that treats the 62,400 Btu/h figure as if it were thousands of watts, skipping the divide by 3412.

D: that is the net figure (18.29 / 1.11), but the question asks for gross.

The maths

  1. Btu/h = 3600 x 1040 / 60 = 62,400
  2. kW = 62,400 / 3412 = 18.29 kW gross

Memory trick:

Imperial: 3600 x 1040 over the dial seconds, then divide by 3412.

Find it in the book

CORGI GID1, 10th Edition, Volume 1, page 238

Reg GID1 Part 11, imperial meter formula

Q3. A boiler data plate shows 20 kW gross and the manufacturer gives no tolerance. Within what measured range would the gas rate normally be considered acceptable?

Show answer

Answer: D. 18.0 kW to 21.0 kW

  • With no manufacturer data, the accepted window is plus 5% or minus 10% of the rated heat input
  • 20 x 1.05 = 21.0 kW, 20 x 0.90 = 18.0 kW

The slight extra tolerance allows for field inaccuracies.

Why the others are wrong:

A: that reverses the limits: minus 5% and plus 10%.

B: that applies plus or minus 5%; the lower limit is minus 10%, not minus 5%.

C: that applies plus or minus 10%; the upper limit is only plus 5%.

The maths

  1. Upper: 20 x 1.05 = 21.0 kW
  2. Lower: 20 x 0.90 = 18.0 kW

Memory trick:

Up five, down ten.

Find it in the book

CORGI GID1, 10th Edition, Volume 1, page 233

Reg GID1 Part 11, permissible gas rate tolerance

Q4. You have finished setting the burner pressure on a non-modulating boiler and refitted the test point screw. What is the next step?

Show answer

Answer: D. Relight and check the test point with non-corrosive LDF

  • Procedure order: zero gauge, turn off appliance, find test point, connect, run to temperature (about 10 minutes), read and compare, adjust, turn off, remove gauge and replace screw
  • Finally: turn on and check the test point with non-corrosive LDF

A loose test point screw is an easy source of escape.

Why the others are wrong:

A: the test point must be proved gas tight with the appliance running.

B: the gauge is removed before the screw is replaced; the final check is for gas tightness.

C: zeroing the gauge is the first step, done before connecting it.

Memory trick:

Last job on any test point: bubbles.

Find it in the book

CORGI GID1, 10th Edition, Volume 1, page 241

Reg GID1 Part 11, testing burner pressures

Q5. A domestic NG installation should be designed so the pressure drop between the meter outlet and each appliance inlet, at maximum load, does not exceed what?

Show answer

Answer: B. 1 mbar

  • NG: maximum 1 mbar drop from meter outlet to appliance inlet at full load
  • LPG: maximum 2.0 mbar drop from the final regulator to all appliances

Pipe sizing aims to keep the pressure at the appliance close to the meter outlet setting.

Why the others are wrong:

A: 2.0 mbar is the figure given for LPG installations from the final regulator.

C: the stated maximum for NG is 1 mbar, not 0.5 mbar.

D: a 4 mbar drop would leave many appliances under-gassed; the limit is 1 mbar.

Memory trick:

NG one, LPG two.

Find it in the book

CORGI GID1, 10th Edition, Volume 1, page 233

Reg GID1 Part 11, introduction

Q6. When checking a thermocouple, what range of output should it generate?

Show answer

Answer: C. 10 mV to 30 mV

  • A thermocouple is two dissimilar metals joined at the tip
  • When heated it generates 10 mV to 30 mV to hold the electromagnetic valve open
  • Thermocouples cannot be repaired; replace when burnt out

Check tip position, cleanliness and lead condition too.

Why the others are wrong:

A: this is ten times higher than the stated range.

B: this is too low to hold in a typical electromagnetic valve.

D: the stated range is 10 mV to 30 mV.

Memory trick:

Thermocouple: ten to thirty millivolts.

Find it in the book

CORGI GID1, 10th Edition, Volume 2, page 13

Reg GID1 Part 12, thermoelectric device