Q1. A homeowner is prosecuted under the Regulations over a newly fitted outside tap that does not comply. What defence does Regulation 7(2) give the homeowner?

Show answer

Answer: A. Proof an approved contractor did and certified the work

  • Reg 7(2): an owner or occupier has a defence if the work was done by or under the direction of an approved contractor, and that contractor certified it complied.
  • Reg 8 extends the same defence to the section 73 offences of contaminating, wasting and misusing water.

This is a strong reason for clients to use approved contractors.

Why the others are wrong:

B: lack of knowledge is not a defence under the Regulations.

C: a product warranty does not prove compliant installation and is not the statutory defence.

D: the length of time in use is not a defence for a non-compliant installation.

Memory trick:

Approved contractor plus certificate equals the client's shield.

Reg Water Fittings Regs reg 7(2)

Q2. A notice under Regulation 5 normally has to include a plan of the premises and a diagram of the pipework. For which of these proposals can the plan and diagram be left out?

Show answer

Answer: A. Installing a bath holding 250 litres to the overflow

  • Reg 5(3)(d): a plan and pipework diagram are needed except for Table items 4(a) baths, 4(c) showers, 4(h) garden watering and 5 ponds/pools.
  • The notice must still give names, addresses, a description of the work and the location and use of the premises.

A large bath only needs the basic details, not drawings.

Why the others are wrong:

B: reverse osmosis (item 4(e)) is not one of the items excused from the plan and diagram.

C: item 4(g) still needs a plan and pipework diagram with the notice.

D: item 4(d) is not excused, so a plan and diagram are needed.

Memory trick:

Baths, showers, sprinklers and ponds: no drawings needed.

Reg Water Fittings Regs reg 5(3)(d)

Q3. A plumber is replacing a bath in a house with a large freestanding model. The data sheet says it holds 265 litres filled to the rim and 228 litres filled to the centre line of the overflow. Does this bath need advance notice to the water undertaker?

Show answer

Answer: B. No, it is not over 230 litres at the overflow centre line

  • Table item 4(a): notice is needed for a bath holding more than 230 litres, measured to the centre line of the overflow.
  • The rim (brim-full) volume is irrelevant to the test.

This bath holds 228 litres at the overflow centre line, which is not more than 230 litres, so no notice is needed for the bath itself.

Why the others are wrong:

A: the table measures bath capacity to the centre line of the overflow, not to the rim.

C: only baths over 230 litres to the overflow centre line appear in the notification table.

D: the bath item applies to any premises, including houses.

The maths

Measure used by the table: capacity to overflow centre line = 228 litres.
Threshold: more than 230 litres.
228 is not more than 230, so the bath is not notifiable.

Memory trick:

Fill to the overflow line, not the brim: over 230 means notify.

Reg Water Fittings Regs reg 5, Table item 4(a)

Q4. A metered mains connection supplies a three-week outdoor car show, used only for washing vehicles, and no water can return through the meter. The Regulations do not apply to these fittings. Which change would bring them back within the Regulations?

Show answer

Answer: C. Running the event for seven weeks without written consent

  • Reg 2(2): the Regulations do not apply to fittings on a supply for purposes other than domestic or food production, where:
  • the water is metered;
  • the supply lasts no more than one month, or three months with the undertaker's written consent;
  • no water can return through the meter.

Seven weeks without written consent exceeds one month, so the exemption is lost.

Why the others are wrong:

A: the location indoors or outdoors is not one of the exemption conditions.

B: the supply would still be metered, so this does not affect the exemption.

D: the number of outlets is not a condition of the exemption.

Memory trick:

Non-domestic, metered, a month (three with consent), no return: miss one and the regs apply.

Reg Water Fittings Regs reg 2(2)

Q5. A water undertaker thinks one Schedule 2 requirement is inappropriate for an unusual installation at a hospital. What is the correct route to relax it?

Show answer

Answer: D. The undertaker applies to the regulator, who must wait a month after notice

  • Reg 11(1): where a Schedule 2 requirement seems inappropriate, the water undertaker applies to the regulator.
  • Reg 11(2) and (4): the undertaker gives notice as directed, and the regulator cannot authorise until one month after that notice, considering any objections.
  • Reg 13: disputes over refusal to apply for a relaxation go to arbitration.

Once authorised, the undertaker relaxes the requirement on the authorised terms.

Why the others are wrong:

A: relaxations are authorised by the regulator, not the local authority; ten working days is the consent period.

B: only the water undertaker can apply to the regulator for a relaxation.

C: the undertaker needs the regulator's authorisation before it can relax a Schedule 2 requirement.

Memory trick:

Undertaker asks, regulator decides, nobody rushes: one month minimum.

Reg Water Fittings Regs reg 11

Q6. A plumber starts building a 12,000 litre pond that tops itself up automatically from the mains, without telling the water undertaker. If convicted, what is the maximum penalty under Regulation 7?

Show answer

Answer: B. A fine not exceeding level 3 on the standard scale

  • Reg 7(1)(b): starting a Table operation without giving notice is an offence.
  • A pond over 10,000 litres filled automatically from the mains is Table item 5.
  • Penalty: on summary conviction, a fine not exceeding level 3 on the standard scale.

The same penalty applies to working without consent or breaching a consent condition.

Why the others are wrong:

A: the Regulations set the maximum at level 3, not level 5.

C: offences under reg 7 are dealt with on summary conviction with a level 3 maximum fine.

D: the Regulations provide for a fine on summary conviction, not a fixed penalty notice.

Memory trick:

Break the water rules, face a level 3.

Reg Water Fittings Regs reg 7(1)

Want 54 more WRAS Water Regs questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.