WRAS Water Regs: Installation requirements practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

21 of our 60 Water Regulations (WRAS) (WRAS-WATER-REGS) questions are on installation requirements, about 35% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. An installer fits a large replacement storage cistern with the float valve inlet and the outlet both at the same end, a few centimetres apart. What is the concern under Schedule 2?

Show answer

Answer: D. Water at the far end will stagnate instead of circulating

  • Sch 2 para 16(5): a storage cistern must be of an appropriate size, with connections positioned to allow free circulation and prevent areas of stagnant water.
  • Inlet and outlet together short-circuit the flow and leave the rest of the cistern standing.

Put the inlet and outlet at opposite ends so water turns over.

Why the others are wrong:

A: air entrainment is about outlet height, not the inlet and outlet being close together.

B: inlet position does not stop the float valve shutting off.

C: overflow capacity is not affected by where the inlet and outlet sit.

Memory trick:

In one end, out the other: keep it moving.

Reg Water Fittings Regs Sch 2 para 16(5)

Q2. A landlord's loft cistern has a sheet of plywood resting loosely on top and no lagging. Which pair of requirements does it fail?

Show answer

Answer: B. A cover to exclude light and insects, and thermal insulation

  • Sch 2 para 16(4)(b): a cover positioned to exclude light and insects.
  • Sch 2 para 16(4)(c): thermal insulation to minimise freezing or undue warming.

A loose board lets in light and insects, and an unlagged loft cistern can freeze in winter and warm up in summer.

Why the others are wrong:

A: the Regulations do not require a lock or a 10°C figure.

C: the cover must exclude light and insects, and a heater is not required.

D: the cover is not required to be airtight; insulation is to minimise freezing and undue warming.

Memory trick:

Cistern needs a hat and a coat: lid for light and bugs, lagging for cold and heat.

Reg Water Fittings Regs Sch 2 para 16(4)(b),(c)

Q3. During a kitchen refit the customer wants the new 15 mm copper cold feed to the island run directly in the sand and cement screed so nothing shows. What do the Regulations say about this?

Show answer

Answer: C. It is not allowed: no water fitting may be embedded in a solid floor

  • Sch 2 para 7(1): no water fitting shall be embedded in any wall or solid floor.
  • A pipe enclosed in a chase or duct is a concealed fitting under para 7(5), which is treated differently from one embedded in solid.

Screeding a pipe in solid makes it impossible to inspect, repair or replace without breaking out the floor.

Why the others are wrong:

A: the no-joints rule is about concealed fittings; embedding in a solid floor is banned outright.

B: coating does not help; the ban on embedding in a wall or solid floor is absolute.

D: there is no depth figure that makes embedding acceptable.

Memory trick:

Embedded = entombed: never in solid walls or floors.

Reg Water Fittings Regs Sch 2 para 7(1)

Q4. A plumber fits a new close-coupled WC fed from the mains. Where must a servicing valve be fitted under Schedule 2?

Show answer

Answer: C. On the inlet pipe next to the flushing cistern

  • Sch 2 para 16(2): every inlet to a storage cistern, combined feed and expansion cistern, WC flushing cistern or urinal flushing cistern needs a servicing valve on the inlet pipe adjacent to the cistern.

This lets the fill valve be changed without isolating the whole house.

Why the others are wrong:

A: the main stopvalve does not satisfy the need for a valve beside the cistern.

B: the valve controls the supply to the cistern, not the flush outlet.

D: WC flushing cisterns are specifically included.

Memory trick:

Every cistern gets a valve at the door: inlet, adjacent.

Reg Water Fittings Regs Sch 2 para 16(2)

Q5. A cold supply to the kitchen tap is to be run up through the airing cupboard right alongside the cylinder and the heating flow and return. What temperature limit should the installer be designing to avoid?

Show answer

Answer: C. Cold water warmed above 25°C

  • Sch 2 para 9: a pipe supplying cold water for domestic use to a tap must, so far as reasonably practicable, keep the water not above 25°C.
  • Running it tight against hot pipes defeats this; reroute or insulate.

Warm cold water lets bacteria grow, which is why the limit exists.

Why the others are wrong:

A: 40°C is far too warm for a cold drinking supply.

B: 20°C is not the figure; the Regulations use 25°C.

D: 60°C is nowhere near a cold water figure; the Regulations set 25°C.

Memory trick:

Cold stays cool: under 25.

Reg Water Fittings Regs Sch 2 para 9

Q6. An office toilet block is being refitted with pressure flushing valves on the WCs. Tests show 1.0 litre per second available at the appliances. Can they be used?

Show answer

Answer: B. No, at least 1.2 litres per second must be achievable

  • Sch 2 para 25(1)(b): no pressure flushing valve may be installed in a house, or in any other building where a minimum flow of 1.2 l/s cannot be achieved at the appliance.

At 1.0 l/s the flush would be poor, so the valves are not permitted here.

Why the others are wrong:

A: offices can use them, but only if 1.2 l/s is achievable at the appliance.

C: a backflow device does not overcome the flow rate condition.

D: they are banned in houses, and elsewhere only where 1.2 l/s cannot be achieved.

Memory trick:

Flushing valves: never in a house, and need 1.2 to flow.

Reg Water Fittings Regs Sch 2 para 25(1)(b)