CITB Refrigeration and AC: Core: general safety practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

16 of our 200 CITB HS&E Specialist Test: Refrigeration and Air Conditioning (CITB-SPEC-RAAC) questions are on core: general safety, about 8% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. On a 110 volt centre-tapped-to-earth site supply, what is the maximum voltage to earth?

Show answer

Answer: B. 55 volts

  • A 110V supply system centre-tapped to earth means the maximum voltage to earth should not exceed 55V.
  • This effectively eliminates the risk of death and greatly reduces injury.

Cordless tools are also a good choice on site.

Why the others are wrong:

A: 110 V is the voltage between the two conductors, not to earth.

C: 230 V is normal mains voltage.

D: 25 V relates to extra low voltage, not a 110 V CTE system.

Memory trick:

110 CTE: 55 to earth.

Find it in the book

HSE HSG150 (2006), page 94

Reg HSE HSG150, para 479

Q2. According to HSG150, about what share of faults or damage in portable electrical equipment can a visual inspection find?

Show answer

Answer: A. About 95%

  • A visual inspection can detect about 95% of faults or damage.
  • Before use, check for bare wires, damaged covering, taped joints, cracked plugs and burn marks.

Some faults, like loss of earth continuity, need testing.

Why the others are wrong:

B: HSG150 gives a much higher figure for visual inspection.

C: visual checks find far more than a quarter of faults.

D: visual checks find most faults; that is why they are so important.

Memory trick:

Look first: 95% of faults show.

Find it in the book

HSE HSG150 (2006), page 95

Reg HSE HSG150, para 484

Q3. You are using a nail gun to fix pipe clips. What eye protection does HSG150 recommend?

Show answer

Answer: D. Shatter-proof goggles

  • Goggles and safety spectacles protect against flying objects, eg when using a nail gun; they should be shatter-proof.
  • UV from welding needs specialist goggles or shields.

Check the manufacturer's specification.

Why the others are wrong:

A: sunglasses are not designed to stop flying objects.

B: specialist welding protection is for UV, not nail guns.

C: flying objects are a risk however short the task.

Memory trick:

Nail gun: shatter-proof goggles.

Find it in the book

HSE HSG150 (2006), page 104

Reg HSE HSG150, para 539

Q4. You are helping set a concrete plinth for a condensing unit. Why does HSG150 say Wellington boots are essential?

Show answer

Answer: A. Wet cement can cause severe skin burns

  • Wellington boots are essential in preventing burns from wet cement or concrete.
  • When mixed with water, the cement becomes highly corrosive and can cause severe burns.

Gloves also protect the hands from cement dermatitis.

Why the others are wrong:

B: the hazard described is chemical burns, not weight.

C: the stated reason is protection from corrosive wet cement.

D: HSG150 gives a health reason, not just a site rule.

Memory trick:

Wet cement burns: wear wellies.

Find it in the book

HSE HSG150 (2006), page 104

Reg HSE HSG150, para 538

Q5. Workers want to dry wet overalls by hanging them on the electric heater in the drying room. What does HSG150 warn?

Show answer

Answer: C. Many fires start this way, by overheating

  • Many fires have been caused by placing clothing on electrical heaters to dry, making the appliance overheat.
  • Electrical heaters should have a high-temperature cut-out or be properly ventilated.

Use a proper drying area, separate from the eating area.

Why the others are wrong:

A: covering a heater can make it overheat at any setting.

B: an unattended overheating heater is even more dangerous.

D: HSG150 warns about electrical heaters overheating.

Memory trick:

Clothes on heaters start fires.

Find it in the book

HSE HSG150 (2006), page 14

Reg HSE HSG150, para 65

Q6. A fire starts in an electrical distribution board on site. Which extinguisher does HSG168 match to electrical fires?

Show answer

Answer: C. Carbon dioxide (CO2)

  • Wood, paper and cloth: water, foam or multi-purpose dry powder.
  • Flammable liquids: dry powder or foam. Electrical items: carbon dioxide (CO2) or dry powder.

Only tackle a fire if it is safe and you are trained.

Why the others are wrong:

A: water is for wood, paper and cloth, and must not be used on electrical fires.

B: foam is listed for flammable liquids and must not be used on electrical fires.

D: HSG168 lists CO2 or dry powder for electrical items, not wet chemical.

Memory trick:

Electrical fire: CO2.

Find it in the book

HSE HSG168 (3rd edition, 2022), page 51

Reg HSE HSG168 (3rd edition, 2022), para 293

Want 194 more CITB Refrigeration and AC questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other CITB Refrigeration and AC topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic