Q1. What does HSE advise before plugging in or unplugging a tool?

Show answer

Answer: C. Switch off the tool and the socket where possible

  • Where possible, tools and power socket outlets should be switched off before plugging in or unplugging.
  • Switch off and unplug equipment before cleaning or making adjustments.

Simple habits prevent many electrical injuries.

Why the others are wrong:

A: tools should be switched off first.

B: the RCD is tested with its test button.

D: this damages the cable and connections.

Memory trick:

Off, then plug.

Find it in the book

HSE INDG231 (rev1, 2012), page 4

Reg HSE INDG231, work safely

Q2. What does HSE say about normal mains voltage of 230 V AC?

Show answer

Answer: A. It can kill

  • The main hazards include contact with live parts causing shock and burns.
  • Normal mains voltage, 230 volts AC, can kill.

Even non-fatal shocks can cause falls from ladders and platforms.

Why the others are wrong:

B: 230 V can kill in any conditions, though wet makes it worse.

C: contact with 230 V live parts can cause fatal shock.

D: a fuse protects the circuit, not the person.

Memory trick:

230 volts can kill.

Find it in the book

HSE INDG231 (rev1, 2012), page 1

Reg HSE INDG231, what are the hazards?

Q3. The RCD keeps tripping when you plug in your drill. What does this tell you?

Show answer

Answer: D. There is a fault; check it before using it again

  • If an RCD trips, it is a sign there is a fault: check the system before using it again.
  • Never bypass an RCD; if it trips often and no fault is found, consult the manufacturer.

Damaged equipment should be taken out of use.

Why the others are wrong:

A: an RCD must never be bypassed.

B: a bigger fuse would not fix the fault the RCD has found.

C: a trip is a sign of a fault that must be checked.

Memory trick:

RCD trips? Find the fault.

Find it in the book

HSE INDG231 (rev1, 2012), page 3

Reg HSE INDG231, provide a safety device

Q4. How should two lengths of flexible cable be joined?

Show answer

Answer: A. With proper connectors or cable couplers

  • Use proper connectors or cable couplers to join lengths of cable.
  • Do not use strip connector blocks covered in insulating tape.

The outer sheath should be firmly clamped where the cable enters plugs and equipment.

Why the others are wrong:

B: twisted and taped joints are unsafe.

C: this is not a proper connector.

D: HSE says not to use strip connectors covered in tape.

Memory trick:

Couplers, not choc block and tape.

Find it in the book

HSE INDG231 (rev1, 2012), page 2

Reg HSE INDG231, provide safe and suitable equipment

Q5. Which extinguishers are suitable for a fire involving electrical equipment?

Show answer

Answer: C. Carbon dioxide or dry powder

  • For electrical items, use a carbon dioxide (CO2) or dry powder extinguisher.
  • Wood, paper and cloth: water, foam or multi-purpose powder; flammable liquids: powder or foam.

Dry powder does not cool and can reduce visibility.

Why the others are wrong:

A: water must not be used on electrical fires.

B: foam must not be used on electrical fires.

D: water and foam must not be used on electrical fires.

Memory trick:

Electrics: CO2 or powder.

Find it in the book

HSE HSG168 (3rd edition, 2022), pages 51 to 52

Reg HSE HSG168, paragraph 293 and Figure 17

Q6. How should a fire point on site be made easy to identify?

Show answer

Answer: B. With a mainly red stand or a proper safety sign

  • Identify a fire point by a stand that is substantially red or an appropriate safety sign.
  • Fire extinguishers should be on hooks or stands to keep them off the ground.

Extinguishers are also needed for specific activities such as hot work.

Why the others are wrong:

A: this is not the marking described.

C: this is not the marking described.

D: extinguishers should be on hooks or stands, off the ground.

Memory trick:

Fire point: red and signed.

Find it in the book

HSE HSG168 (3rd edition, 2022), page 51

Reg HSE HSG168, paragraph 291

Want 194 more CITB Plumbing (JIB) questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other CITB Plumbing (JIB) topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic