CITB Demolition: Structural stability, methods and exclusion zones practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

30 of our 150 CITB HS&E Specialist Test: Demolition (CITB-SPEC-DEM) questions are on structural stability, methods and exclusion zones, about 20% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. Under CDM 2015, when may an explosive charge be fired during a demolition?

Show answer

Answer: C. Only when steps ensure no one is at risk from blast or flying material

  • A charge may be fired only if suitable and sufficient steps ensure no person is exposed to injury.
  • This covers the explosion and projected or flying material.

Explosives must also be stored, transported and used safely and securely.

Why the others are wrong:

A: a warning alone does not ensure no one is exposed.

B: timing alone does not ensure no one is exposed.

D: charge weight alone does not ensure no one is exposed.

Memory trick:

No one in range, then fire.

Find it in the book

HSE L153 (CDM 2015), page 51

Reg CDM 2015, regulation 21(2)

Q2. What is the limitation of netting on the scaffold around a demolition?

Show answer

Answer: D. Most netting will only hold light material

  • Protect passers-by with toe boards, brick guards and netting.
  • But most netting only retains light material; fans or covered walkways may be needed where the risk is high.

Sheeting must not make the scaffold unstable.

Why the others are wrong:

A: netting is not limited to the top lift.

B: netting is a protection for work at height, not something removed for it.

C: netting does retain light debris; heavier items need other protection.

Memory trick:

Nets catch the small stuff, fans catch the rest.

Find it in the book

HSE HSG150 (3rd edition, 2006), page 106

Reg HSG150 (2006), paragraph 555

Q3. Why must the demolition survey check for pre-stressed or post-tensioned concrete members?

Show answer

Answer: D. They are a source of substantial stored energy

  • HSG150 asks whether pre-stressed or post-stressed concrete beams are present.
  • CDM guidance lists pre- or post-tensioned members as sources of substantial stored energy.

Releasing that energy without a planned method can cause sudden failure.

Why the others are wrong:

A: asbestos is a separate survey item, not a feature of pre-stressing.

B: stored energy, not weight, is the issue.

C: they need a planned method because of the stored energy.

Memory trick:

Tensioned steel is a loaded spring.

Find it in the book

HSE HSG150 (3rd edition, 2006), page 80; HSE L153 (CDM 2015), page 81

Reg HSG150 (2006), paragraph 395; CDM 2015, L153 Appendix 4 paragraph 3(c)

Q4. At the end of the working day, what should be done with the ladders giving access to the demolition scaffold?

Show answer

Answer: B. Remove them so trespassers cannot climb up

  • At the end of each day, remove access ladders from excavations and scaffolds.
  • Also cover excavations, immobilise plant and lock away hazardous substances.

Children may get onto sites despite fencing.

Why the others are wrong:

A: a tied ladder gives easy access to children at night.

C: a ladder left on the ground can be put back up.

D: a ladder by the hoarding helps people climb in.

Memory trick:

Ladders off at night, no climbers in sight.

Find it in the book

HSE HSG150 (3rd edition, 2006), page 106

Reg HSG150 (2006), paragraph 553

Q5. A crane will lift salvaged plant out of the building over the public footway. What may be needed?

Show answer

Answer: C. A temporary extension of the perimeter and a pedestrian diversion

  • A banksman may be enough for deliveries, but higher-risk work such as crane use may need the site perimeter temporarily extended.
  • Alternative pedestrian routes may need local authority permission.

Avoid lifting over public areas where possible.

Why the others are wrong:

A: timing gaps does not keep the public out of the danger area.

B: a banksman alone may do for deliveries, not crane lifts over the public.

D: fewer people is not the same as nobody under the load.

Memory trick:

Crane over the path? Move the fence and the people.

Find it in the book

HSE HSG151 (2nd edition, 2009), page 11

Reg HSE HSG151 (2009), paragraph 41

Q6. Which demolition condition can put a building into a higher fire hazard category?

Show answer

Answer: B. Oil-contaminated wooden floors or linings

  • Higher hazard areas are where rapid fire spread with heavy smoke could occur.
  • Examples include demolition or refurbishment involving oil-contaminated wooden floors or linings.

The hazard category can change as the work progresses.

Why the others are wrong:

A: clean concrete adds little to the fire load.

C: bare brick is not combustible.

D: bare steel is not a combustible fire load.

Memory trick:

Oily timber burns fast.

Find it in the book

HSE HSG168 (3rd edition, 2022), page 42

Reg HSE HSG168 (2022), Table 2 notes, higher-hazard areas

Want 144 more CITB Demolition questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other CITB Demolition topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic