Q1. Under CDM 2015, when may an explosive charge be fired during a demolition?
Show answer
Answer: C. Only when steps ensure no one is at risk from blast or flying material
- A charge may be fired only if suitable and sufficient steps ensure no person is exposed to injury.
- This covers the explosion and projected or flying material.
Explosives must also be stored, transported and used safely and securely.
Why the others are wrong:
A: a warning alone does not ensure no one is exposed.
B: timing alone does not ensure no one is exposed.
D: charge weight alone does not ensure no one is exposed.
Memory trick:
No one in range, then fire.
Find it in the book
HSE L153 (CDM 2015), page 51