CITB Demolition: Core: general safety practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

12 of our 150 CITB HS&E Specialist Test: Demolition (CITB-SPEC-DEM) questions are on core: general safety, about 8% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. You find a faulty disc cutter in the tool store. What should happen to it?

Show answer

Answer: A. Take it out of use, label it DO NOT USE and keep it secure

  • Suspect or faulty equipment should be taken out of use, labelled DO NOT USE and kept secure until examined by a competent person.
  • Damaged equipment is then repaired competently or disposed of.

This stops someone else picking it up by mistake.

Why the others are wrong:

B: a note elsewhere does not stop the next person using it.

C: faulty equipment should not be used at all.

D: repairs must be done by someone competent.

Memory trick:

Tag it, bag it, lock it away.

Find it in the book

HSE INDG231(rev1) (2012), page 4

Reg HSE INDG231, work safely

Q2. An extension lead has a cut through its outer sheath. What is the correct repair?

Show answer

Answer: A. Replace the damaged length and use proper couplers

  • Replace damaged sections of cable completely.
  • Join lengths with proper connectors or cable couplers, not strip connectors wrapped in tape.

Extension leads are especially liable to damage on site.

Why the others are wrong:

B: tape is not a repair; the damaged section must be replaced.

C: strip connector blocks covered in tape must not be used to join cables.

D: a damaged sheath leaves the lead unsafe even if the cores look intact.

Memory trick:

Cut it out, couple it up, never tape it up.

Find it in the book

HSE INDG231(rev1) (2012), page 2

Reg HSE INDG231, provide safe and suitable equipment

Q3. Which of these is a common electrical fire risk on site?

Show answer

Answer: A. Using flat twin and earth cable as an extension lead

  • Common electrical fire faults include flat twin and earth used as extension leads, overloaded sockets and coiled leads not unwound.
  • Daisy-chaining extension leads is also a risk.

Only competent people should alter a site electrical installation.

Why the others are wrong:

B: 110 V supplies reduce risk; they are not a fire fault.

C: proper couplers are the right way to join leads.

D: unwinding reels fully avoids overheating; coiled leads are the risk.

Memory trick:

Twin and earth stays in the wall, not on the floor.

Find it in the book

HSE HSG168 (3rd edition, 2022), page 27

Reg HSE HSG168 (2022), paragraph 134

Q4. According to HSE, what causes over half of the fatal electrical accidents each year?

Show answer

Answer: B. Contact with overhead power lines

  • Over half of fatal electrical accidents are caused by contact with overhead lines.
  • Electricity can flash over even if plant does not touch the line.

If possible, have lines switched off by giving the owner enough notice.

Why the others are wrong:

A: faulty tools cause shocks, but are not over half of the deaths.

C: leads are easily damaged, but are not the main cause of deaths.

D: buried cable strikes are serious but are not the cause of over half of deaths.

Memory trick:

Look up before you lift up.

Find it in the book

HSE INDG231(rev1) (2012), pages 4 to 5

Reg HSE INDG231, overhead power lines

Q5. Battery tools are not suitable for a task on a demolition site. Which supply is recommended for portable power tools?

Show answer

Answer: D. 110 V centre-tapped to earth

  • Limit the voltage to the lowest needed: battery tools are safest.
  • Otherwise use tools run from a 110 V centre-tapped-to-earth supply.

If 230 V must be used, an RCD gives extra protection.

Why the others are wrong:

A: 230 V carries more shock risk, and overloaded adaptors can cause fire.

B: 400 V is not used for hand tools and is far more dangerous.

C: existing building sockets at 230 V do not reduce the shock risk.

Memory trick:

No battery? Go yellow, go 110.

Find it in the book

HSE INDG231(rev1) (2012), pages 2 to 3

Reg HSE INDG231, reduce the voltage

Q6. On a demolition job, what rated tripping current should an RCD used to protect people have?

Show answer

Answer: C. Not more than 30 mA

  • RCDs for protecting people have a rated tripping current of not more than 30 mA.
  • An RCD detects some, but not all, faults and switches off fast.

Use the test button regularly to check it works.

Why the others are wrong:

A: 100 mA is too high for personal protection.

B: 300 mA is too high for personal protection.

D: 13 A is a fuse rating, not an RCD sensitivity.

Memory trick:

Thirty milliamps keeps you breathing.

Find it in the book

HSE INDG231(rev1) (2012), page 3

Reg HSE INDG231, provide a safety device

Want 144 more CITB Demolition questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other CITB Demolition topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic