CITB Demolition: Core: occupational health practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

12 of our 150 CITB HS&E Specialist Test: Demolition (CITB-SPEC-DEM) questions are on core: occupational health, about 8% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. Which noise figure must not be exceeded, even after allowing for the hearing protection being worn?

Show answer

Answer: A. 87 dB daily or weekly exposure

  • The exposure limits are 87 dB daily or weekly exposure and 140 dB peak.
  • These limits take account of hearing protection worn.

The action values (80 and 85 dB) are set without any allowance for protectors.

Why the others are wrong:

B: 85 dB is the upper action value, not the limit.

C: 80 dB is the lower action value, not the limit.

D: 137 dB is the upper peak action value; the peak limit is 140 dB.

Memory trick:

87 is the line you never cross, even with muffs on.

Find it in the book

HSE INDG362(rev2) (2012), page 6

Reg Control of Noise at Work Regulations 2005 (HSE INDG362), exposure limits

Q2. Which symptom is a typical sign of hand-arm vibration syndrome?

Show answer

Answer: B. Fingers going white, then red and painful as they recover

  • HAVS symptoms include tingling and numbness, loss of grip strength and fingers going white (blanching), then red and painful on recovery.
  • Symptoms can become permanent with continued exposure.

Cold and damp conditions make attacks worse.

Why the others are wrong:

A: ringing in the ears is tinnitus, linked to noise.

C: red, cracked skin is a sign of dermatitis.

D: breathlessness and coughing point to lung disease from dust.

Memory trick:

White fingers mean vibration has got in.

Find it in the book

HSE INDG175(rev3) (2012), page 1

Reg Control of Vibration at Work Regulations 2005 (HSE INDG175), symptoms of HAVS

Q3. When estimating workers' noise exposure for the risk assessment, how should their ear defenders be treated?

Show answer

Answer: C. Make no allowance for them at all

  • When estimating exposure, do not make any allowance for personal hearing protection.
  • The estimate is then compared with the 80 and 85 dB action values.

Protection is only factored in when checking the 87 dB and 140 dB limits.

Why the others are wrong:

A: protectors are only considered when checking the exposure limit, not when estimating exposure.

B: there is no flat deduction in the estimate.

D: even full-day wearing is not allowed for in the estimate.

Memory trick:

Estimate naked ears.

Find it in the book

HSE INDG362(rev2) (2012), page 4

Reg Control of Noise at Work Regulations 2005 (HSE INDG362), estimating noise exposure

Q4. In the COSHH order of priority for control measures, which comes last?

Show answer

Answer: A. Personal protective equipment such as respirators

  • The COSHH order starts with eliminating or substituting the substance, then changing, enclosing and extracting.
  • PPE comes last, and it must fit the wearer.

If PPE is used with other controls, they must all work together.

Why the others are wrong:

B: local extraction comes before PPE.

C: enclosure comes before extraction and PPE.

D: using a safer form is near the top of the list.

Memory trick:

Masks are the last line, not the first.

Find it in the book

HSE INDG136(rev5) (2012), page 5

Reg COSHH 2002 (HSE INDG136), choosing control measures

Q5. A worker used a resin for years with no problem, but now his skin reacts every time he touches it. What is this?

Show answer

Answer: A. Sensitising dermatitis, an allergic reaction

  • Sensitising dermatitis is an allergic reaction that can appear after weeks, months or years of use with no ill effects.
  • Once it develops, any future exposure will cause a reaction.

Resins, cement and solvents are common skin hazards in construction.

Why the others are wrong:

B: irritant dermatitis depends on the strength and length of contact, not a new allergy.

C: oil acne is linked to bitumen products, not a sudden reaction to a resin.

D: carpal tunnel syndrome affects the hand nerves, not the skin.

Memory trick:

Sensitised once, sensitive for life.

Find it in the book

HSE HSG150 (3rd edition, 2006), page 84

Reg HSG150 (2006), paragraph 419

Q6. Using a modern, well-maintained hammer-action breaker, roughly how long does it take to reach the vibration exposure action value?

Show answer

Answer: D. About 15 minutes

  • Hammer-action tools: EAV in about 15 minutes, ELV in about one hour.
  • Non-hammer tools: EAV in about one hour, ELV in about four hours.

Breaking out concrete by hand can quickly put operatives at risk of HAVS.

Why the others are wrong:

A: about an hour of hammer tool use is when the limit value is likely to be reached.

B: four hours is the guide for non-hammer tools reaching the limit value.

C: a full shift on a breaker would be far above the limit value.

Memory trick:

Hammer: a quarter hour to act, one hour to the limit.

Find it in the book

HSE INDG175(rev3) (2012), page 3

Reg Control of Vibration at Work Regulations 2005 (HSE INDG175), likely exposure times

Want 144 more CITB Demolition questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other CITB Demolition topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic