CITB HS&E Operatives: Working environment and legal duties practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

60 of our 300 CITB Health, Safety and Environment Test: Operatives (CITB-HSE-OPS) questions are on working environment and legal duties, about 20% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. You see a workmate cutting blocks in a way that could injure people working below. What should you do?

Show answer

Answer: D. Report it to the person in control of the work

  • Under CDM 2015 guidance, everyone involved in a project, including workers, has a duty to report work that puts anyone in danger.
  • The report goes to the person in control of the work, who should encourage workers to stop work and report dangerous conditions.

Speaking up early is one of the simplest ways an operative can prevent an accident.

Why the others are wrong:

A: everyone on a project, including workers, has a duty to report dangerous working, not wait for an injury.

B: the guidance says dangerous working is reported to the person in control of the work, who can act straight away.

C: danger needs reporting when you see it, not weeks later.

Memory trick:

See it, say it, to the person in charge.

Find it in the book

HSE L153 (CDM 2015), page 25

Reg HSE L153, para 68

Q2. On a small site with only two or three people working, what may be an adequate way to raise the alarm in an emergency?

Show answer

Answer: C. An air horn

  • A large site with many work locations will probably need bells or sirens at a number of places.
  • On small sites with only two or three people, an air horn may be adequate.

Whatever is used must be distinctive, audible over site noise and known to everyone.

Why the others are wrong:

A: HSG150 does not suggest texts; the warning must be heard by everyone.

B: a written note does not alert people in an emergency.

D: that is what a large site with many work locations is likely to need.

Memory trick:

Small site, big horn.

Find it in the book

HSE HSG150 (3rd ed), page 17

Reg HSE HSG150, para 81

Q3. A site is choosing its toilets. Which type does HSG150 say should be used wherever possible?

Show answer

Answer: B. Toilets flushed by water and connected to mains drainage

  • Wherever possible, toilets should be flushed by water and connected to mains drainage.
  • If not, use toilets with a built-in water supply and drainage tank.
  • If neither is possible, chemical toilets may be provided.

The number of toilets needed depends on how many people work on site.

Why the others are wrong:

A: chemical toilets are the last option, used only if the other two are not possible.

C: self-contained tank units are the second choice, for when mains drainage is not possible.

D: toilets need to be provided on site and easy to reach from where the work is done.

Memory trick:

Mains first, tank second, chemical last.

Find it in the book

HSE HSG150 (3rd ed), page 12

Reg HSE HSG150, paras 47 and 48

Q4. You have been trained to use some access equipment, but on this job you think using it as instructed would be unsafe. What should you do?

Show answer

Answer: C. Stop and ask for further instructions before carrying on

  • Workers must use equipment properly, in line with training and instructions.
  • If they think that would be unsafe, they should seek further instructions before continuing.
  • They must report any safety hazard they identify.

Speaking up before you start is part of your legal duty.

Why the others are wrong:

A: if you think it would be unsafe, you should seek further instructions first.

B: the concern should be raised before continuing.

D: workers should seek further instructions, not invent their own method.

Memory trick:

Feels unsafe? Stop and ask.

Find it in the book

HSE INDG401(rev2), page 6

Reg Work at Height Regulations 2005 (HSE INDG401)

Q5. On a project with several contractors, who must make sure every site worker receives a suitable site induction?

Show answer

Answer: B. The principal contractor

  • On a multi-contractor project, the principal contractor must ensure every worker gets a suitable, site-specific induction.
  • Where the principal contractor has not provided one, the worker's own contractor must.

Inductions should highlight the particular risks and controls on that site.

Why the others are wrong:

A: the client appoints the principal contractor, but the induction duty sits with the principal contractor.

C: the principal designer manages the pre-construction phase, not site inductions.

D: HSE enforces the law; it does not induct workers.

Memory trick:

PC = Provides the induction Course.

Find it in the book

HSE L153 (CDM 2015), page 40

Reg HSE L153, para 133

Q6. Where should fire escape routes from a site lead?

Show answer

Answer: B. To a safe place where people can gather and be accounted for

  • Escape routes must stay available and unobstructed.
  • They must give access to a safe place where people can assemble and be accounted for.
  • On a small site, the pavement outside may be enough.

Counting people at the assembly point shows whether anyone is missing.

Why the others are wrong:

A: a cabin on site may not be a safe place in a fire.

C: escape routes should lead people to safety, normally at ground level.

D: routes must lead to a safe place, not a dead end.

Memory trick:

Get out, gather, get counted.

Find it in the book

HSE HSG150 (3rd ed), page 18

Reg HSE HSG150, para 88

Want 294 more CITB HS&E Operatives questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other CITB HS&E Operatives topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic