Q1. A load is being slung for lifting. Where should its centre of gravity be?

Show answer

Answer: B. Directly beneath the hook

  • Loads must be slung so they are in balance with their centre of gravity beneath the hook.
  • The centre of gravity is often not in the middle, especially on plant.

An unbalanced load can shift or slip out of its slings.

Why the others are wrong:

A: a centre of gravity above the lift points is shown as unstable.

C: an off-centre load can shift or slip from its slings.

D: strong slings do not stop an unbalanced load from shifting.

Memory trick:

Hook over the heavy heart.

Find it in the book

HSE HSG150 (3rd ed), page 69

Reg HSE HSG150, para 332, Figure 41

Q2. Where should a signaller position themselves when guiding a reversing vehicle?

Show answer

Answer: D. In a protected position where the driver can see them

  • Wherever possible give signallers a protected position from which they can work in safety.
  • They should be easily distinguished, and drivers must stop if they cannot see the signaller.

Signallers are often the person closest to the moving vehicle.

Why the others are wrong:

A: standing in the vehicle's path puts the signaller at risk of being struck.

B: the signaller needs to see the area behind and be seen from outside.

C: hi-vis helps but does not replace a safe, visible position.

Memory trick:

Safe spot, in sight.

Find it in the book

HSE HSG150 (3rd ed), page 62

Reg HSE HSG150, paras 302 to 303

Q3. If 230 V tools must be used, they should be protected by an RCD. What rated tripping current should an RCD for protecting people have?

Show answer

Answer: C. No more than 30 mA

  • RCDs for protecting people have a rated tripping current (sensitivity) of not more than 30 mA.
  • HSG150 adds they should have no time delay and be tested by pressing the test button daily.

An RCD still does not give the safety of cordless or 110 V tools.

Why the others are wrong:

A: 100 mA is too high for protecting people.

B: 300 mA is far too high to protect people from electric shock.

D: 13 A is a fuse rating, not an RCD sensitivity.

Memory trick:

Thirty milliamps saves lives.

Find it in the book

HSE INDG231(rev1), page 3; HSE HSG150 (3rd ed), page 94

Reg HSE INDG231, Provide a safety device

Q4. Why can plant be dangerous near overhead power lines even if it never touches them?

Show answer

Answer: B. Electricity can flash over from the line to nearby plant

  • INDG231: electricity can flash over from overhead lines even though plant does not touch them.
  • Over half of fatal electrical accidents each year are from contact with overhead lines.

Consult the line owner about safe working distances.

Why the others are wrong:

A: lines are only switched off if arranged in advance with the owner.

C: INDG231 warns electricity can flash over without contact.

D: electricity can jump the gap to nearby equipment.

Memory trick:

No touch needed to get a shock.

Find it in the book

HSE INDG231, page 5

Reg HSE INDG231, overhead power lines

Q5. An excavator is loading loose spoil into a tipper lorry. A labourer climbs onto the back of the lorry to level the load as it is tipped in. Is this allowed?

Show answer

Answer: D. No, not unless a safe place of work is provided for them

  • Nobody may remain on a vehicle during the loading or unloading of loose material.
  • The exception is where a safe place of work is provided and maintained.
  • Nobody may ride on a vehicle except in a safe place provided for that purpose.

People on loads get buried, struck or thrown off.

Why the others are wrong:

A: loading loose material is the danger, even with the lorry parked.

B: being seen does not make the back of the lorry safe.

C: PPE does not provide the safe place of work the regulation requires.

Memory trick:

Loose load going in? Get off the lorry.

Find it in the book

HSE L153 (CDM 2015), page 55

Reg CDM 2015, regulation 28(5) (HSE L153)

Q6. When must a mobile crane have a rated capacity indicator (automatic safe load indicator) fitted?

Show answer

Answer: C. When it can lift more than one tonne

  • A rated capacity indicator must be fitted when the crane can lift more than one tonne.
  • Capacity falls with radius: a 20 tonne crane may be needed to lift one tonne at distance.

The crane needs a current thorough examination report.

Why the others are wrong:

A: loads should not be lifted over people at all.

B: the trigger is more than one tonne; 20 tonnes is the radius example.

D: the requirement depends on the crane capacity, not the contract type.

Memory trick:

Over a tonne? Indicator on.

Find it in the book

HSE HSG150 (3rd ed), page 68

Reg HSE HSG150, para 328

Want 294 more CITB HS&E Operatives questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other CITB HS&E Operatives topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic