AM2 Knowledge Test: Health and safety practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

51 of our 240 AM2 Assessment of Applied Knowledge (Section E) (AM2) questions are on health and safety, about 21% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. A labourer is to be trained to use the site's 110 V circular saw. What training does the guidance say anyone using work equipment like this will need?

Show answer

Answer: C. Initial training, then refresher training

  • There are no general age restrictions in law on using work equipment.
  • Anyone using it must be competent, which needs initial and refresher training.

Competence comes from proper training that is kept up to date, not from age or home experience.

Why the others are wrong:

A: there is no general age rule; what matters is training and competence.

B: competence needs initial and refresher training, not a one-off demo.

D: home experience is no substitute for proper training on site equipment.

Memory trick:

Train once, then train again.

Reg ECS HS&E (work equipment)

Q2. A homeowner has hired your firm, the only one on the job, to rewire her house. She asks whether she now has CDM 2015 duties as the client. What's the answer?

Show answer

Answer: C. No, for a domestic client those duties pass to your firm

  • Initial verification and some maintenance of fixed installations fall within CDM 2015.
  • For private domestic clients, the contractor, or the principal contractor if there is more than one, undertakes the client's duties.

On a one-firm domestic rewire, that means you.

Why the others are wrong:

A: building control checks Building Regulations compliance, it does not take on CDM client duties.

B: for private domestic clients the duties pass to the contractor.

D: the length of the job does not change who takes on the client duties for a domestic client; the contractor does.

Memory trick:

Domestic client? The duties come home to the contractor.

Find it in the book

IET Guidance Note 3 (2022 edition), page 13

Reg CDM Regulations 2015

Q3. You've laid a rubber protection ramp over your 110 V lead where it crosses a site road used by dumpers. What else does the guidance say should be provided?

Show answer

Answer: B. A 'Ramp Ahead' sign to warn drivers

  • The cable must be protected from damage by passing traffic, for example with a rubber protection ramp.
  • A 'Ramp Ahead' sign warns road traffic of the ramp.

A damaged lead is a shock risk as well as a trip hazard.

Why the others are wrong:

A: a spare lead adds nothing to protecting the cable or warning traffic.

C: tape gives no protection; the ramp protects and a sign warns.

D: boards can be knocked aside and are not part of the guidance.

Memory trick:

Ramp it and sign it.

Reg ECS HS&E (work equipment)

Q4. Your generator has leaked oil onto bare ground beside the van. Why must the oil-soaked soil NOT go in the general waste skip?

Show answer

Answer: A. It is classed as hazardous waste and must be kept separate

  • Oil-contaminated waste is classed as hazardous waste (special waste in Scotland).
  • It must be segregated and recovered or disposed of in an approved way.
  • A drip tray or bund under the generator would have caught the leak.

Putting it in the general skip would be an offence under waste law.

Why the others are wrong:

B: weight is not the reason; the oil makes it hazardous waste.

C: cost is not the legal reason; oily soil is hazardous waste.

D: soil soaked with oil is itself hazardous waste.

Memory trick:

Oily soil = hazardous, keep it apart.

Reg Hazardous Waste Regulations

Q5. You lean a ladder against a wall to reach a cable tray bracket. The top rests 5.2 m up the wall and the foot is 0.8 m out. Using the 1 in 4 rule, what should you do?

Show answer

Answer: D. Move the foot out 0.5 m, to 1.3 m

  • The correct angle is about 75 degrees, which is 1 out for every 4 up.
  • Foot distance = 5.2 / 4 = 1.3 m, so the foot must move out by 0.5 m.

A ladder set too steep can tip backwards; too shallow and the foot can slide out.

Why the others are wrong:

A: that divides the height by 8 and makes the ladder even steeper.

B: 5.2 / 0.8 is 6.5 up for every 1 out, so the ladder is much too steep.

C: that is 1 out for every 2 up, which is far too shallow and the foot could slip.

The maths

Required distance out = height / 4 = 5.2 / 4 = 1.3 m
Current distance = 0.8 m
Move out by 1.3 - 0.8 = 0.5 m

Memory trick:

One out, four up: divide the height by four.

Reg Work at Height Regs 2005

Q6. Which item of site kit is normally coloured yellow to show it is part of the 110 V system?

Show answer

Answer: B. The 230 V to 110 V step-down transformer

  • Yellow is the usual colour of cables, socket-outlets, plugs and transformers used with a 110 V supply.
  • The transformer is what most commonly reduces 230 V to 110 V on site.

If you see yellow kit on site, expect 110 V.

Why the others are wrong:

A: these are not part of the 110 V system and are not normally yellow.

C: these are mains voltage, not 110 V, so they are not yellow.

D: call points are fire safety equipment and have nothing to do with the 110 V supply.

Memory trick:

Yellow = one-ten.

Reg ECS HS&E (site electrical supplies)

Want 234 more AM2 Knowledge Test questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other AM2 Knowledge Test topics

Revise this topic