PAT 2377-77: User checks and formal visual inspection practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

26 of our 150 In-Service Inspection and Testing of Electrical Equipment (PAT) (2377-77) questions are on user checks and formal visual inspection, about 17% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. A user fits a traditional incandescent lamp of higher wattage into a modern table lamp marked for low-energy lamps only. What is the main hazard the Code of Practice highlights?

Show answer

Answer: B. Fire, as the luminaire may not cope with the extra heat

  • Lamps above the recommended rating, or changes such as different shades, create a risk of fire.
  • Some modern luminaires are designed for low-energy lamps and cannot take the heat of incandescent lamps.
  • Some low-energy lamps also have cooling needs and should be checked for overheating.

Wrong lamp, wrong heat, fire risk.

Why the others are wrong:

A: the concern raised is overheating and fire, not shock.

C: an oversized lamp is a heat problem, not an earth leakage problem.

D: the Code raises the extra heat of incandescent lamps, not dimmer compatibility.

Memory trick:

Big bulb in a low-energy fitting = fire risk.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 58

Reg CoP Section 7, Figure 7.2

Q2. Inside a plug on a bench grinder you find no loose strands but a long length of bare copper showing on the live core. Is this acceptable?

Show answer

Answer: A. No, there should be no excessive copper showing on any conductor

  • There should be no excessive copper showing on any of the conductors.
  • There should be no loose strands of copper showing.
  • The earth wire should be connected inside the plug, not detached.

Bare copper and stray strands are both fails.

Why the others are wrong:

B: both loose strands and excessive bare copper are separate defects.

C: the rule applies to any of the conductors.

D: moulded plugs are not opened; this is a check of rewireable plugs.

Memory trick:

No bare copper, no stray strands.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 111

Reg Appendix 6, Table A6.1

Q3. Which of these does the Code of Practice give as an example of an isolator rather than a functional switch?

Show answer

Answer: C. A cooker switch

  • Functional switches: a light switch on a wall, the switch on a 13 A socket-outlet.
  • Isolators: the isolator for a bathroom fan, a cooker switch.
  • A plug and socket-outlet is not classed as an isolator but can give effective isolation.

Isolators are there to cut the supply for work, not for daily use.

Why the others are wrong:

A: this is given as an example of a functional switch.

B: a light switch is given as an example of a functional switch.

D: an appliance on/off switch is for functional use, not isolation.

Memory trick:

Cooker switch and fan isolator: isolators. Light switch: functional.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 60

Reg CoP 8.3

Q4. Which of these is normally part of a user check?

Show answer

Answer: C. An external look at the item, its flex and its plug

  • User checks are usually limited to an external visual check with no dismantling.
  • No removal of covers and no opening of plugs.
  • Internal inspection is done during the formal visual inspection (Section 8).

Anything that needs a screwdriver is beyond the user check.

Why the others are wrong:

A: user checks involve no dismantling; internal inspection belongs to the formal visual inspection.

B: opening plugs is part of the formal visual inspection, not a user check.

D: testing is done in a combined inspection and test, not by the user.

Memory trick:

User = look, don't unscrew.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 57

Reg CoP Section 7

Q5. Before switching off a shop's card-payment server to inspect it, what must the inspector first obtain?

Show answer

Answer: D. Permission from the responsible person or dutyholder

  • Before switching off equipment, permission of the responsible person or dutyholder is needed.
  • Otherwise there may be disruption or serious loss to the business.
  • The same applies before disconnecting communication links.

Ask before you switch off.

Why the others are wrong:

A: calibration matters for testing, but permission is what is needed before switching off.

B: the network operator has no role in switching off a customer's equipment.

C: permission comes from the responsible person or dutyholder, not each user.

Memory trick:

Ask first, switch off second.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 61

Reg CoP 8.3.2

Q6. Why might fitting a lower-rated fuse than recommended cause problems with an item such as a motor-driven floor polisher?

Show answer

Answer: A. Starting surges on switch-on may blow the fuse

  • Many items have considerable inrush currents when first energized.
  • Causes include the starting surge of motors and the charging currents of capacitors.
  • A fuse below the recommended rating may blow on these surges.

Too small a fuse fails on the switch-on surge, not because of a fault.

Why the others are wrong:

B: fuse rating does not change the earth loop impedance of the circuit.

C: a lower rating gives closer, not weaker, protection of the flex.

D: BS 1362 fuses come in a range of ratings; the issue is inrush current.

Memory trick:

Motors and capacitors gulp current at switch-on.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 59

Reg CoP 8.1

Want 144 more PAT 2377-77 questions? Start a free timed mock.