PAT 2377-77: Law, responsibilities and competence practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

25 of our 150 In-Service Inspection and Testing of Electrical Equipment (PAT) (2377-77) questions are on law, responsibilities and competence, about 17% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. A test operative must disconnect a permanently connected water heater to test it. What competence does the CoP stress for this work?

Show answer

Answer: D. Safe isolation procedures

  • Operatives working on installed equipment that needs disconnection must be competent in safe isolation.
  • They must safely isolate and reconnect equipment permanently connected to a supply.
  • Guidance: HSE HSG85 and Electrical Safety First's Best Practice Guide 2.

This is a step up from testing plug-in items.

Why the others are wrong:

A: IP codes relate to enclosure protection, not safely disconnecting equipment.

B: calibration knowledge is useful, but the CoP stresses safe isolation for disconnecting installed equipment.

C: record-keeping is part of the role but not the key competence for disconnection.

Memory trick:

Fixed kit? Isolate first, test second.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 43

Reg CoP 5.4.1

Q2. Under the Housing (Scotland) Act 2006 repairing standard, when must a private landlord ensure the property meets the standard?

Show answer

Answer: D. At tenancy start, and whenever told of defects

  • The repairing standard is in Chapter 4 of the Housing (Scotland) Act 2006.
  • It must be met (a) at the start of the tenancy and (b) at all times during the tenancy where the landlord is made aware of defects.
  • It covers the installation, equipment, heating, lighting and hot water.

Supplied equipment must be in a reasonable state of repair and proper working order.

Why the others are wrong:

A: the CoP gives no fixed interval for the repairing standard; it is tied to the tenancy.

B: the standard also applies at all times during the tenancy when the landlord is made aware of defects.

C: the duty is on the landlord at set points, not triggered by the council.

Memory trick:

Scotland: start right, stay right.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 28

Reg CoP 3.1.7

Q3. In the PUWER Approved Code of Practice (L22), what does "efficient" refer to in the maintenance requirement?

Show answer

Answer: B. Its effect on health and safety

  • L22 states that "efficient" relates to how the equipment's condition might affect health and safety.
  • It is not concerned with productivity.

A slow but safe machine meets the requirement; a fast but unsafe one does not.

Why the others are wrong:

A: L22 states efficient is not concerned with productivity.

C: energy use is not what L22 means by efficient.

D: repair speed is not part of the meaning given in L22.

Memory trick:

Efficient = safe, not speedy.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 31

Reg CoP 3.3

Q4. A shop owner says, "The Electricity at Work Regulations don't require test records, so I won't keep any." What is the best response?

Show answer

Answer: B. True, but then compliance is hard to demonstrate

  • There is no requirement in the EAWR to keep maintenance records.
  • Without records, compliance cannot be readily demonstrated.
  • A log helps monitor the scheme, acts as an inventory and can spot unauthorised items brought in by staff.

The CoP therefore recommends records are kept; PUWER may also require them.

Why the others are wrong:

A: the CoP states there is no requirement in the EAWR to keep maintenance records.

C: the CoP specifically recommends that records are kept and maintained.

D: the EAWR contain no record-keeping requirement for any class of equipment.

Memory trick:

No record, no proof.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 26

Reg CoP 3.1.4

Q5. An office building's emergency lighting fails. It is not itself an electrical hazard, but the loss of lighting is. Which regulations impose a maintenance regime for this type of system?

Show answer

Answer: D. Workplace (Health, Safety and Welfare) Regulations 1992

  • The Workplace Regulations are concerned with the consequences of equipment and system failures.
  • They impose maintenance on emergency lighting, fire alarms, powered doors, escalators and moving walkways.
  • The EAWR are about the installation being safe, not what happens when it stops working.

The Workplace Regulations also cover non-electrical items such as fencing and window restrictors.

Why the others are wrong:

A: these cover design and construction of machinery, and the CoP does not consider them further.

B: the EAWR do not deal with the consequences of a malfunctioning electrical system.

C: these deal with BS 1363 plugs on consumer equipment, not system maintenance.

Memory trick:

Workplace Regs: what happens when it doesn't Work.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 27

Reg CoP 3.1.5

Q6. A retailer imports mains hairdryers fitted with a non-UK plug for sale to consumers. What do the Plugs and Sockets etc. (Safety) Regulations 1994 allow?

Show answer

Answer: A. Use of an approved conversion plug

  • Mains equipment sold to UK consumers must be fitted with an approved BS 1363 plug.
  • For imports with a non-standard plug, an approved conversion plug may be used.

This is why you see sealed conversion plugs on some imported items.

Why the others are wrong:

B: the Regulations require an approved BS 1363 plug or an approved conversion plug, not a loose adaptor.

C: the Regulations apply to mains equipment sold to consumers in the UK, including imports.

D: the equipment must be supplied fitted with an approved plug or approved conversion plug.

Memory trick:

Sold in the UK = BS 1363 or an approved converter.

Find it in the book

IET Code of Practice for In-service Inspection and Testing of Electrical Equipment, 5th Edition, page 29

Reg CoP 3.1.12

Want 144 more PAT 2377-77 questions? Start a free timed mock.

Start a free mock