PAS 2035/2030 Retrofit: Retrofit roles, responsibilities and competence practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

24 of our 160 PAS 2035/2030 Retrofit Standards (Warm Homes) (PAS-RETROFIT) questions are on retrofit roles, responsibilities and competence, about 15% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. According to PAS 2035:2023, whose interests must the Retrofit Coordinator identify, protect and document?

Show answer

Answer: D. Both the client's interest and the public interest

  • Clause 6.1.3: the Retrofit Coordinator's role is to identify, protect and document both the client's interest and the public interest.
  • They oversee the project from inception to completion, covering assessment, design, installation and evaluation.

Where clients conflict, the coordinator states which takes precedence and why.

Why the others are wrong:

A: the coordinator does not act for the installer's commercial interest.

B: funders may be clients, but the public interest is also protected.

C: the duty covers the client and the public, regardless of who pays.

Memory trick:

Client and public, both protected.

Find it in the book

BSI PAS 2035:2023, page 11

Reg PAS 2035:2023, clause 6.1.3

Q2. Which qualification does PAS 2035:2023 name as the standard route for a Retrofit Coordinator?

Show answer

Answer: B. Level 5 Diploma in Retrofit Coordination and Risk Management

  • A.2.1: a Retrofit Coordinator holds the Level 5 Diploma in Retrofit Coordination and Risk Management, or can show they are working towards it via RPEL or a registered course.
  • The OCN NI Level 5 Extended Certificate in Retrofitting Domestic Properties is also accepted.

Building-related qualifications are prerequisites for the Level 5 Diploma.

Why the others are wrong:

A: this is the route for a Retrofit Assessor under A.1.1.

C: MCIOB is one of the routes for a Retrofit Designer under A.3.7.

D: this is the extra qualification needed for traditional buildings, not the core coordinator qualification.

Memory trick:

Coordinator is Level 5.

Find it in the book

BSI PAS 2035:2023, page 33

Reg PAS 2035:2023, Annex A, A.2.1

Q3. Under PAS 2030:2023, what must the Retrofit Installer confirm before installation starts?

Show answer

Answer: C. A Retrofit Coordinator is appointed and their role is known to all staff

  • PAS 2030 Clause 4: before installation the installer confirms a Retrofit Coordinator has been appointed under PAS 2035.
  • The coordinator's identity and role must be made known to all personnel on the project, and the coordinator given access to work in progress.

Everyone on site should know who the coordinator is.

Why the others are wrong:

A: the installer confirms an appointment; it need not employ the coordinator.

B: a new EPC is recommended after handover, not required before installation.

D: the evaluator works after handover; method statements are the installer's job.

Memory trick:

No coordinator, no start.

Find it in the book

BSI PAS 2030:2023, page 8

Reg PAS 2030:2023, Clause 4

Q4. The only measure proposed is a single proprietary insulation system from one supplier. Who could be the Retrofit Designer?

Show answer

Answer: D. A specifier trained and approved by its supplier

  • A.3.2: where the only measure is a single proprietary system, the designer is a specialist designer or specifier trained and approved by the manufacturer or supplier of that system.
  • Alternatively they can be qualified under A.3.7.

The system holder knows the system's details and limits.

Why the others are wrong:

A: assessors are not a designer route for proprietary systems.

B: the evaluator role relates to post-handover evaluation.

C: an installer card is not a design approval from the supplier.

Memory trick:

Proprietary system: supplier-approved designer.

Find it in the book

BSI PAS 2035:2023, page 33

Reg PAS 2035:2023, Annex A, A.3.2 (first occurrence)

Q5. Under PAS 2035:2023, who advises the client on which statutory, safety or ecological consents the retrofit work will need?

Show answer

Answer: A. The Retrofit Coordinator

  • 8.2.7: the Retrofit Coordinator advises the client on statutory, health and safety or ecological approvals.
  • They then either apply on the client's behalf or cooperate with others appointed to apply.

Approvals can include planning, listed building consent, party wall notices and Building Regulations.

Why the others are wrong:

B: the assessor identifies planning constraints, but the coordinator advises on approvals.

C: certification bodies do not advise clients on approvals.

D: DESNZ is not named in clause 8.2.7.

Memory trick:

Coordinator steers the approvals.

Find it in the book

BSI PAS 2035:2023, page 16

Reg PAS 2035:2023, clause 8.2.7

Q6. A project combines external wall insulation, loft insulation and floor insulation, all meeting at junctions. Who could act as the Retrofit Designer?

Show answer

Answer: A. An architect registered with the Architects Registration Board

  • A.3.7: with three or more interacting fabric measures, the Retrofit Designer shall be an MCIAT/FCIAT, an ARB architect, an MCIOB/FCIOB or a chartered building surveyor (MRICS/FRICS).
  • The same applies to fabric insulation or windows on high-rise or system-built dwellings.

Complex interfaces need a building professional to design the junctions.

Why the others are wrong:

B: that route (A.3.5) covers two interacting fabric measures, not three or more.

C: MCS designers qualify for a single MCS measure under A.3.4, not fabric packages.

D: three or more interacting fabric measures need an A.3.7 professional.

Memory trick:

Three or more fabric measures: call a chartered pro.

Find it in the book

BSI PAS 2035:2023, page 34

Reg PAS 2035:2023, Annex A, A.3.7

Want 154 more PAS 2035/2030 Retrofit questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other PAS 2035/2030 Retrofit topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (GOV.UK). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic