PAS 2035/2030 Retrofit: Installer requirements and quality management (PAS 2030) practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

24 of our 160 PAS 2035/2030 Retrofit Standards (Warm Homes) (PAS-RETROFIT) questions are on installer requirements and quality management (pas 2030), about 15% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. The Retrofit Coordinator cannot visit site in person. For which measure can they NOT rely on third-party digital evidence?

Show answer

Answer: B. External wall insulation

  • 9.2: if an in-person visit is not possible, digital evidence from a third party is allowed only for listed measures (e.g. loft, cavity wall, boiler replacement, solar PV).
  • Any EEM not listed, such as external wall insulation, needs an in-person inspection; so does a listed measure that penetrates another fabric EEM.

Complex fabric work needs eyes on site.

Why the others are wrong:

A: party cavity wall insulation is on the list allowing digital evidence.

C: boiler replacement is on the list allowing digital evidence.

D: loft insulation is on the list allowing digital evidence.

Memory trick:

EWI needs boots on the ground.

Find it in the book

BSI PAS 2035:2023, page 22

Reg PAS 2035:2023, clause 9.2

Q2. During a pre-installation building inspection the inspector finds bats roosting in the loft. What must be done?

Show answer

Answer: D. Record it and tell the installer and the Retrofit Coordinator

  • Clause 7.2.7: where species or plants that could be specially protected are found, the inspector includes it in the inspection record.
  • The presence is made known to the Retrofit Installer and the Retrofit Coordinator.

Examples given include bats, birds, butterflies and dormice.

Why the others are wrong:

A: the record and the installer and coordinator must be informed.

B: the presence of protected species must be recorded and reported first.

C: species that may be protected must not simply be removed.

Memory trick:

Bats in the loft? Write it down, pass it on.

Find it in the book

BSI PAS 2030:2023, page 16

Reg PAS 2030:2023, clause 7.2.7

Q3. An installer is contracted on a design and build basis. What does PAS 2030:2023 require in the contract documents?

Show answer

Answer: A. The design and installer roles are clearly split

  • 7.9.2: on a design and build basis, the roles of Retrofit Designer and Retrofit Installer are clearly defined and distinguished in the contract.
  • This permits claims against either or both if the installation is defective.

Clear roles mean clear liability.

Why the others are wrong:

B: this is not the requirement in 7.9.2.

C: the coordinator role is separate and must still be appointed.

D: the aim is to allow claims, not prevent them.

Memory trick:

Design and build? Separate the hats on paper.

Find it in the book

BSI PAS 2030:2023, page 17

Reg PAS 2030:2023, clause 7.9.2

Q4. Under PAS 2030:2023, when may the Retrofit Installer start installing measures?

Show answer

Answer: B. Once a site-specific PAS 2035 design is obtained and validated

  • Clause 5.1: for each installation the installer obtains a location-specific retrofit design conforming to PAS 2035 for the complete package.
  • Installation shall not commence until the design has been obtained and validated.

No design, no drill.

Why the others are wrong:

A: a contract alone is not enough without a validated design.

C: an EPC is not the trigger in PAS 2030 clause 5.1.

D: material delivery does not satisfy the design requirement.

Memory trick:

Get it, check it, then fit it.

Find it in the book

BSI PAS 2030:2023, page 9

Reg PAS 2030:2023, clause 5.1

Q5. An installer asks the Retrofit Coordinator for a toolbox talk on an unfamiliar product, and the coordinator refuses. What must the installer do?

Show answer

Answer: A. Ask the coordinator to justify why no briefing is given

  • Clause 6.5.2: briefings shall always be requested in set cases, including new or unusual products the installer is not familiar with.
  • If a request is refused, the installer asks the Retrofit Coordinator to justify why a briefing need not or cannot be given.

Toolbox talks explain the design intent and installation sequence.

Why the others are wrong:

B: the first step is to ask for a justification.

C: the briefing on design intent comes from the coordinator.

D: PAS 2030 requires the installer to seek a justification.

Memory trick:

Refused a briefing? Ask why.

Find it in the book

BSI PAS 2030:2023, page 13

Reg PAS 2030:2023, clause 6.5.2

Q6. What must a Retrofit Installer's process continuity plan ensure?

Show answer

Answer: D. Unfinished jobs pass to another installer to complete

  • Clause 7.5: if unforeseen circumstances stop the installer finishing, all uncompleted installations are transferred to another Retrofit Installer and completed in accordance with the design and PAS 2030.
  • Where the installer is a subcontractor, the main contractor confirms a plan is in place.

Clients should not be left with half a retrofit.

Why the others are wrong:

A: the plan transfers work to another installer.

B: unfinished work must be completed, not signed off.

C: the plan is about completing work, not refunds.

Memory trick:

If you stop, someone else finishes.

Find it in the book

BSI PAS 2030:2023, page 16

Reg PAS 2030:2023, clause 7.5

Want 154 more PAS 2035/2030 Retrofit questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other PAS 2035/2030 Retrofit topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.