44 of our 120 Part L Energy Efficiency (Domestic Heating) (PART-L-ENERGY) questions are on heating systems and efficiency, about 37% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. A Condensing Boiler Installation Assessment shows exceptional circumstances apply to a natural gas boiler replacement. What is the lowest SEDBUK 2009 efficiency AD L then accepts?

Show answer

Answer: B. 78%

  • In exceptional circumstances the gas table (2026 Table 5.3; 2021 Table 6.2) allows SEDBUK 2009 efficiencies of 78% for natural gas and 80% for LPG.
  • Exceptional circumstances are defined in the ODPM Condensing Boiler Installation Assessment Procedure guide.

Otherwise the normal 92% ErP minimum applies.

Why the others are wrong:

A: 84% is the exceptional circumstances figure for an oil-fired regular boiler.

C: 80% is the exceptional circumstances figure for LPG, not natural gas.

D: 75% (SEDBUK 2009) is the minimum for a gas range cooker with an integral boiler.

Memory trick:

Natural gas 78, LPG 80: LPG gets the extra two.

Find it in the book

Approved Document L Vol 1 2021 (incl. 2023), page 40; 2026 edition, page 46

Reg Approved Document L Vol 1, 2021 (incl. 2023 amendments) Table 6.2 and note 2; 2026 edition Table 5.3 and note 2

Q2. A gas-fired warm air system is being installed in an existing dwelling. To which standard should it be installed?

Show answer

Answer: C. BS 5864

  • A gas warm air system in an existing dwelling should be installed to BS 5864 (2026 para 5.11; 2021 para 6.4).
  • New or replacement ductwork should be insulated to BS 5422.

Time and temperature controls are also required.

Why the others are wrong:

A: BS 7593 is for preparing and commissioning wet central heating systems.

B: BS EN 1264-4 covers underfloor heating.

D: BS 3198 covers copper hot water storage combination units.

Memory trick:

Warm air: 5864.

Find it in the book

Approved Document L Vol 1 2021 (incl. 2023), page 41; 2026 edition, page 47

Reg Approved Document L Vol 1, 2021 (incl. 2023 amendments) 6.4(a); 2026 edition 5.11(a)

Q3. A solar system has a heat exchanger between the solar primary and the secondary system. What minimum heat exchanger area should be provided?

Show answer

Answer: A. 0.1m² for every 1m² of net absorber area

  • At least 0.1m² of heat exchanger area (or equivalent) is needed per 1m² of net absorber area (2026 para 5.45; 2021 para 6.46).
  • Dedicated solar storage is also sized from the absorber area.

Too small a coil wastes the collected heat.

Why the others are wrong:

B: this is a tenth of the AD L figure.

C: this is ten times the AD L figure.

D: AD L links the area to the absorber area.

Memory trick:

One tenth of the collector area.

Find it in the book

Approved Document L Vol 1 2021 (incl. 2023), page 48; 2026 edition, page 53

Reg Approved Document L Vol 1, 2021 (incl. 2023 amendments) 6.46; 2026 edition 5.45

Q4. A gas-fired fixed independent space heater is being fitted as the primary heating in an existing flat. What minimum efficiency does AD L set?

Show answer

Answer: D. 63% gross (70% net)

  • The gas efficiency table for existing dwellings sets 63% gross (equivalent to 70% net) for independent space heating appliances (2026 Table 5.3; 2021 Table 6.2).
  • Gross efficiency is tested using BS EN 1266, BS 7977-1, BS EN 613 or BS EN 13278 as appropriate.

The same figure applies whether the heater is primary or secondary.

Why the others are wrong:

A: 92% is the minimum for gas wet heating boilers, not independent space heaters.

B: 75% is the minimum for a gas range cooker with an integral boiler.

C: 45% is for an inset live fuel-effect fire combined with a back boiler on natural gas.

Memory trick:

Gas space heater: 63 gross, 70 net.

Find it in the book

Approved Document L Vol 1 2021 (incl. 2023), page 40; 2026 edition, page 46

Reg Approved Document L Vol 1, 2021 (incl. 2023 amendments) Table 6.2; 2026 edition Table 5.3

Q5. A continuously burning, manually operated oil-fired vaporising appliance provides secondary heating. What further control does AD L require?

Show answer

Answer: C. None beyond the integral manual controls

  • For a manually operated continuously burning oil vaporising appliance, no further control is needed beyond the integral manual controls (2026 para 5.17; 2021 para 6.10).
  • An electrically operated appliance needs an integral remote or thermostatic control.

This does not apply to appliances converted from another fuel.

Why the others are wrong:

A: AD L asks for nothing beyond the integral manual controls here.

B: this is required for electrically operated appliances, not manual ones.

D: weather compensation is not required for this appliance.

Memory trick:

Manual vaporiser: its own knobs will do.

Find it in the book

Approved Document L Vol 1 2021 (incl. 2023), page 42; 2026 edition, page 48

Reg Approved Document L Vol 1, 2021 (incl. 2023 amendments) 6.10; 2026 edition 5.17

Q6. Electric storage heaters are being installed in an existing house. Which pair of controls does AD L expect?

Show answer

Answer: B. Automatic control of input charge, and adjustable heat release

  • Electric storage heaters need automatic control of input charge (2026 para 5.19; 2021 para 6.12).
  • The rate of heat release should be adjustable, by a damper or other thermostatically controlled method.

This stops the heaters charging fully on mild nights.

Why the others are wrong:

A: AD L asks for automatic charge control and adjustable heat release.

C: the input charge should be controlled automatically.

D: storage heaters have no boiler; this is a wet system control.

Memory trick:

Storage heaters: auto charge, adjustable release.

Find it in the book

Approved Document L Vol 1 2021 (incl. 2023), page 43; 2026 edition, page 49

Reg Approved Document L Vol 1, 2021 (incl. 2023 amendments) 6.12; 2026 edition 5.19

Want 114 more Part L Energy Efficiency questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other Part L Energy Efficiency topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (GOV.UK). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic