CITB Supervisory: Core: occupational health practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

16 of our 200 CITB HS&E Specialist Test: Supervisory (CITB-SPEC-SUP) questions are on core: occupational health, about 8% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. How often are hearing checks usually carried out for workers under health surveillance for noise?

Show answer

Answer: D. Yearly for two years, then every three years

  • Hearing checks are usually done annually for the first two years of exposure, then at three-yearly intervals.
  • They may be more frequent if a problem is found or the risk is high.

Results are reviewed by a suitable doctor, nurse or audiologist.

Why the others are wrong:

A: the usual interval after the first two years is three years.

B: this is more often than the usual pattern in the leaflet.

C: checks are regular, not a one-off.

Memory trick:

One, two, then every three.

Find it in the book

HSE INDG362 (rev2, 2012), page 8

Reg HSE INDG362, 'Health surveillance'

Q2. An operative uses a modern hammer-action breaker. Roughly how long before they reach the HAV exposure action value?

Show answer

Answer: D. About 15 minutes

  • Hammer-action tools: EAV after about 15 minutes, ELV after about one hour.
  • Non-hammer tools: EAV after about one hour, ELV after about four hours.

These are for modern, well-maintained tools; old or damaged tools are worse.

Why the others are wrong:

A: about 1 hour is when a hammer tool is likely to reach the limit value.

B: about 4 hours is the limit value guide for non-hammer tools.

C: hammer tools reach the action value far sooner.

Memory trick:

Hammer tools hit the limit fast.

Find it in the book

HSE INDG175 (rev3, 2012), page 3

Reg HSE INDG175, 'Which tools are most likely to create a risk?'

Q3. Dust from cutting concrete has settled on the floor. How should it be cleaned up?

Show answer

Answer: C. With an M or H class vacuum, or wet methods

  • Do not dry sweep: use a vacuum of dust class M or H, or wet cleaning.
  • Do not use compressed air to remove dust from clothing.

Cleaning methods are part of the safe system of work.

Why the others are wrong:

A: settled dust can be raised again by people and vehicles.

B: compressed air spreads the dust and must not be used on clothing.

D: dry sweeping puts fine silica back into the air.

Memory trick:

Hoover or hose, never brush or blow.

Find it in the book

HSE INDG463 (2024), page 4

Reg HSE INDG463, 'Do not'

Q4. At what daily personal noise exposure is the upper exposure action value reached?

Show answer

Answer: A. 85 dB

  • Lower exposure action value: 80 dB daily or weekly exposure.
  • Upper exposure action value: 85 dB; above this a planned programme of noise control is needed.

The peak values are 135 dB (lower) and 137 dB (upper).

Why the others are wrong:

B: 90 dB is not an action value under the 2005 Regulations.

C: 87 dB is the exposure limit value, allowing for hearing protection.

D: 80 dB is the lower exposure action value.

Memory trick:

80 think, 85 act, 87 never.

Find it in the book

HSE INDG362 (rev2, 2012), page 4

Reg Control of Noise at Work Regulations 2005 (HSE INDG362), exposure action values

Q5. What is the daily exposure limit value (ELV) for hand-arm vibration?

Show answer

Answer: C. 5 m/s² A(8)

  • Exposure action value (EAV): 2.5 m/s² A(8), a clear risk needing management.
  • Exposure limit value (ELV): 5 m/s² A(8), which must not be exceeded.

Both combine the vibration level with the time spent gripping the tool.

Why the others are wrong:

A: 2.5 m/s² A(8) is the exposure action value, not the limit.

B: this is not a hand-arm vibration value in INDG175.

D: this is double the legal limit value.

Memory trick:

Two and a half act, five stop.

Find it in the book

HSE INDG175 (rev3, 2012), page 2

Reg Control of Vibration at Work Regulations 2005 (HSE INDG175)

Q6. How long does silicosis usually take to develop?

Show answer

Answer: B. At least 10 years of exposure

  • Silicosis usually develops after at least 10 years of RCS exposure.
  • There are often no symptoms at first; changes show up on X-ray.

Because it is slow and silent, controls must be used every day.

Why the others are wrong:

A: the leaflet gives at least 10 years as usual.

C: this is far too short for the usual pattern.

D: silicosis usually develops after at least 10 years of RCS exposure.

Memory trick:

Silicosis is slow: ten years and counting.

Find it in the book

HSE INDG463 (2024), page 2

Reg HSE INDG463, 'How can RCS harm your health?'

Want 194 more CITB Supervisory questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other CITB Supervisory topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic