CITB Highway Works: Underground services and excavations practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

40 of our 200 CITB HS&E Specialist Test: Highway Works (CITB-SPEC-HIW) questions are on underground services and excavations, about 20% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. What is a limitation of vacuum excavation near underground services?

Show answer

Answer: C. It does not work in all ground or on concrete

  • Vacuum excavation can be very effective in congested excavations.
  • But it has limits: it will not work on all ground conditions or on materials such as concrete.

Assess the risk from ejected material and from jetting near old cables.

Why the others are wrong:

A: vacuum excavation is a safe method, though jetting needs care.

B: it is very effective in congested excavations.

D: HSE does not issue permits for vacuum excavation.

Memory trick:

Vac is great, but not on concrete.

Find it in the book

HSE HSG47 (3rd edition, 2014), page 25

Reg HSE HSG47, para 111

Q2. You uncover a cable whose end has been sealed in the ground. How should it be treated?

Show answer

Answer: C. As live: pot-ended cables may still be energised

  • 'Pot-ended' or 'bottle-ended' cables are terminated in the ground with a seal.
  • Treat them as live: do not assume they are abandoned, and remember they are hard to detect.

If in doubt about any exposed service, treat it as live.

Why the others are wrong:

A: pot-ended cables should not be assumed abandoned.

B: power cables are terminated this way.

D: pot-ended cables are hard to detect even when live.

Memory trick:

Sealed end, still live.

Find it in the book

HSE HSG47 (3rd edition, 2014), page 21

Reg HSE HSG47, para 89

Q3. Why might a cable locator used in power (hum) mode fail to detect a street lighting cable during the day?

Show answer

Answer: C. Little or no current may be flowing in it

  • Hum detectors pick up the magnetic field from current flowing in a cable.
  • They do not respond to cables with little or no current, eg street lighting in daytime, nor to DC cables or pot-ended cables.

A locator that shows nothing does not prove the ground is clear.

Why the others are wrong:

A: hum detectors do not respond to direct current cables.

B: this is not why hum detection fails.

D: surfaces do not stop the magnetic field being detected.

Memory trick:

No current, no hum.

Find it in the book

HSE HSG47 (3rd edition, 2014), page 20

Reg HSE HSG47, para 85

Q4. A utility plan shows a cable 2 m from the kerb at 600 mm deep. How should you use this information?

Show answer

Answer: A. As a guide only, confirmed by locating and trial holes

  • Plans alone are not sufficient; they guide a thorough site survey.
  • Do not rely on them for distances or depths: kerb lines move, surfaces are regraded and cables get moved.

Use a suitable locator and safe digging to confirm what the plan suggests.

Why the others are wrong:

B: plans are not enough to locate services before work.

C: plans should not be relied on for depth either.

D: even plans claiming to be to scale should not be used for distances.

Memory trick:

Plans point, trial holes prove.

Find it in the book

HSE HSG47 (3rd edition, 2014), page 11

Reg HSE HSG47, paras 39 and 41

Q5. Which statement about emergency work near underground services is correct?

Show answer

Answer: A. It still needs planning and assessment of the risks

  • Emergency work still requires planning and risk assessment, and attempts to get service information.
  • Routine work that could be planned should not be done as emergency work.

Managers must weigh the risk of damaging services against the risk from the emergency itself.

Why the others are wrong:

B: attempts must still be made to get service information.

C: emergency work is about safety, not service targets.

D: emergency work is no excuse for cutting corners.

Memory trick:

Emergency is no excuse.

Find it in the book

HSE HSG47 (3rd edition, 2014), page 18

Reg HSE HSG47, paras 72 to 74

Q6. There are no service records for the verge where you are about to dig a trial hole. What should you assume?

Show answer

Answer: B. Services are present unless shown otherwise

  • Underground services are widespread: assume they are present unless shown otherwise.
  • Older services in particular may not have been recorded.

Use plans, locators and safe digging every time you break ground.

Why the others are wrong:

A: the absence of records is never proof that an area is clear.

C: any type of service could be present.

D: services are often shallower than expected.

Memory trick:

No plan does not mean no pipe.

Find it in the book

HSE HSG47 (3rd edition, 2014), page 5

Reg HSE HSG47, para 3

Want 194 more CITB Highway Works questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other CITB Highway Works topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (DfT, HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic