Working at Height: Ladders and stepladders practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

30 of our 120 Working at Height Awareness (WAH-AWARE) questions are on ladders and stepladders, about 25% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. You need to work with an aluminium ladder near an overhead line on wooden poles. HSG33 says you are unlikely to need extra precautions, other than controlling access, if you can stay at least what distance away, measured at ground level from below the nearest wire?

Show answer

Answer: B. 9 m

  • If you can keep at least 15 m from steel towers and 9 m from wooden poles (measured horizontally at ground level from below the nearest wire), you are unlikely to need extra precautions apart from controlling access.
  • Closer than that, precautions must make sure people can work safely; follow DNO advice.

HSG33 records roof workers killed when aluminium ladders touched 11 kV lines.

Why the others are wrong:

A: 600 mm is the minimum distance from any part of poles, pylons and stay wires.

C: 3 m is the exclusion zone for 11 kV or 33 kV lines, not this ground-level distance.

D: 15 m is the distance given for steel towers, not wooden poles.

Memory trick:

Wood 9, steel 15.

Find it in the book

HSE HSG33 (5th edition, 2020), page 22

Reg HSE HSG33 (2020), para 80

Q2. A risk assessment decides a ladder is right for a short, low-risk task. What does HSE's step-by-step diagram say you should then make sure of?

Show answer

Answer: C. Workers use the right type of ladder for the job

  • If a ladder is correct, further minimise the risk by making sure workers:
  • use the right type of ladder, are competent, use it safely following a safe system of work, and are fully aware of the risks.

Choosing a ladder is the start of managing the risk, not the end.

Why the others are wrong:

A: a harness is not listed as a ladder control in the diagram.

B: no 10 minute limit is set in the diagram.

D: footing is a last resort, not a standard requirement in the diagram.

Memory trick:

Right ladder, right person, right way.

Find it in the book

HSE INDG401(rev2), page 4 (Figure 1)

Reg Work at Height Regulations 2005 (HSE INDG401, Figure 1, 'Using ladders')

Q3. A leaning ladder can't be tied, so a ladder stability device will be used instead. What must the device stop the ladder doing?

Show answer

Answer: A. Running sideways, sliding out or rotating

  • Where tying isn't practicable, use a ladder with an effective stability device.
  • It must make sure the ladder does not run sideways, slide away from the wall or rotate about a stile.

A device that only stops one kind of movement leaves the others.

Why the others are wrong:

B: the device must stop the ladder running sideways, sliding away or rotating.

C: it must also stop sideways movement and rotation about a stile.

D: bounce is not what the guidance says the device must stop.

Memory trick:

Sideways, outwards, twisting: stop all three.

Find it in the book

HSE HSG150 (3rd edition, 2006), page 42

Reg HSE HSG150 (2006), para 222

Q4. Which method of stopping a leaning ladder from slipping is the last resort?

Show answer

Answer: D. Having a workmate foot the ladder

  • Options, in order: tie the ladder (both stiles); use a ladder stability device; wedge the foot.
  • Footing the ladder is the last resort and should be avoided by using other access equipment.

A person footing a ladder can't stop it sliding sideways or the top slipping.

Why the others are wrong:

A: tying is the first option HSE lists.

B: wedging is listed before footing.

C: a stability device is used where tying isn't practicable.

Memory trick:

Feet on the foot: the last resort.

Find it in the book

HSE HSG150 (3rd edition, 2006), page 42

Reg HSE HSG150 (2006), para 222

Q5. The only place a ladder top could rest is against a plastic gutter. What does HSE suggest?

Show answer

Answer: A. Use a stand-off device so it rests on a solid surface

  • The top of the ladder must rest against a solid surface.
  • Ladders should not rest on fragile or insecure surfaces such as cement sheet or plastic guttering.
  • A spreader bar or stand-off device can help.

A gutter can snap or flex and the ladder top then slides away.

Why the others are wrong:

B: new plastic guttering is still an insecure surface.

C: footing doesn't make a weak resting point safe.

D: ladders should not rest on plastic guttering at all.

Memory trick:

Gutter's not a wall: stand it off.

Find it in the book

HSE HSG150 (3rd edition, 2006), page 43

Reg HSE HSG150 (2006), para 227

Q6. What does HSE say you should do to avoid overreaching on a ladder?

Show answer

Answer: B. Keep your belt buckle inside the stiles

  • Do not overreach: keep your belt buckle inside the stiles.
  • Keep both feet on the same rung.

If you can't reach, get down and move the ladder.

Why the others are wrong:

A: both feet should be on the same rung.

C: this is not HSE's test for overreaching.

D: HSE's test is the belt buckle staying inside the stiles.

Memory trick:

Buckle between the stiles.

Find it in the book

HSE HSG150 (3rd edition, 2006), page 42

Reg HSE HSG150 (2006), para 221

Want 114 more Working at Height questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other Working at Height topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic