Q1. You need to work with an aluminium ladder near an overhead line on wooden poles. HSG33 says you are unlikely to need extra precautions, other than controlling access, if you can stay at least what distance away, measured at ground level from below the nearest wire?
Show answer
Answer: B. 9 m
- If you can keep at least 15 m from steel towers and 9 m from wooden poles (measured horizontally at ground level from below the nearest wire), you are unlikely to need extra precautions apart from controlling access.
- Closer than that, precautions must make sure people can work safely; follow DNO advice.
HSG33 records roof workers killed when aluminium ladders touched 11 kV lines.
Why the others are wrong:
A: 600 mm is the minimum distance from any part of poles, pylons and stay wires.
C: 3 m is the exclusion zone for 11 kV or 33 kV lines, not this ground-level distance.
D: 15 m is the distance given for steel towers, not wooden poles.
Memory trick:
Wood 9, steel 15.
Find it in the book
HSE HSG33 (5th edition, 2020), page 22