Q1. You need to let the stores manager at your own firm know, in writing, that a van will collect two cable drums on Friday. Which form of communication suits this best?

Show answer

Answer: A. A short internal memo

  • A memo is internal communication used within an organisation.
  • Memos are not normally used for customers or suppliers.

A short message between colleagues in the same firm is exactly what a memo is for.

Why the others are wrong:

B: formal letters are for external correspondence; a quick internal note does not need one.

C: that records extra work outside the contract, not internal messages.

D: that is signed when goods are received from a supplier.

Memory trick:

Memo stays in-house; letters go out.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 68

Reg Ch2 Memos

Q2. On a 1:100 layout drawing a rectangular kitchen measures 42 mm by 30 mm. What is the actual floor area of the kitchen?

Show answer

Answer: B. 12.6 m²

  • Scale each dimension first: 42 mm x 100 = 4200 mm = 4.2 m; 30 mm x 100 = 3000 mm = 3.0 m.
  • Area = 4.2 x 3.0 = 12.6 m².

Always convert each length to its actual size before multiplying for an area.

Why the others are wrong:

A: this multiplies the drawn millimetre values together without scaling to metres correctly.

C: this adds the two sides and scales the sum, which gives a length, not an area.

D: this scales each side to 42 m and 3 m, so one dimension has been converted wrongly.

The maths

Length = 42 mm x 100 = 4200 mm = 4.2 m
Width = 30 mm x 100 = 3000 mm = 3.0 m
Area = 4.2 x 3.0 = 12.6 m²

Memory trick:

Scale the sides, then multiply.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 54

Reg AC 1.2 Scale drawings

Q3. After fitting a specified type of luminaire, what should be done with a copy of its manufacturer's data sheet?

Show answer

Answer: B. Put it in the job file for the client

  • Read the manufacturer's data sheet before fitting: it gives specific assembly and fixing instructions.
  • A copy should be placed in the job file for the client to receive when the job is completed.
  • User instructions are also placed in the job file for handover.

The client inherits the paperwork needed to operate and maintain the equipment.

Why the others are wrong:

A: the data sheet is needed by the client, not the supplier.

C: the client needs it for future reference and maintenance.

D: it belongs with the installation records handed to the client.

Memory trick:

Read it, fit it, file it.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 53

Reg AC 1.2 Manufacturer's data

Q4. An electrician passes a customer's phone number and address to a friend's company without the customer's consent. Which Act is breached?

Show answer

Answer: B. Data Protection Act

  • The Data Protection Act ensures that personal information is not given out without consent.
  • Passing a customer's details on without consent is a breach.

Customer information collected on job sheets must be kept confidential.

Why the others are wrong:

A: this concerns treating everyone with fairness, dignity and respect, not personal data.

C: this sets out employees' statutory rights.

D: these cover electrical safety at work.

Memory trick:

Customer data stays with you.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 92

Reg Data Protection Act

Q5. Which set of items would a client normally inherit when an installation is handed over?

Show answer

Answer: D. Operation manual, as-fitted drawings, certificates and warranties

  • At handover the client inherits an operation manual plus technical documents such as as-fitted drawings, specification details, the electrical installation certificates required by Part 6, warranties and manufacturers' guides.

In effect you are saying: here is your installation, complete with information on the systems and equipment.

Why the others are wrong:

A: these are internal company records, not handover documents for the client.

B: these relate to pricing the job, not operating the installation.

C: these are internal working documents of the contractor.

Memory trick:

Handover pack: how to run it, where it is, proof it's safe, who guarantees it.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 67

Reg AC 2.2 Handover documents

Q6. Which item would you normally expect to record on your weekly time sheet?

Show answer

Answer: C. Any travelling expenses claimed

  • A time sheet is usually a weekly document.
  • It includes the hours worked, the name of the job and any travelling expenses claimed.
  • Office staff use it to make up wages and bill hours to jobs.

Fill it in accurately: it affects both your pay and the job's costing.

Why the others are wrong:

A: that belongs on a daywork sheet or variation order.

B: that is recorded on the delivery note.

D: that information is on a job sheet.

Memory trick:

Time sheet: hours, job, travel.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 69

Reg AC 2.4 Time sheets