QELTK3/002: Heat-producing and water-conservation technologies practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

47 of our 150 Environmental Legislation and Technologies (QELTK3-002) questions are on heat-producing and water-conservation technologies, about 31% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. A house needs 9,000 kWh of heat a year. Its heat pump gives 3 kWh of heat for every 1 kWh of electricity used. How much electricity will the compressor use in a year?

Show answer

Answer: D. 3,000 kWh

  • The text gives 3 to 4 kWh of heat per 1 kWh of electricity.
  • Electricity = heat needed ÷ heat per kWh.
  • 9,000 ÷ 3 = 3,000 kWh.

The other 6,000 kWh comes free from the environment.

Why the others are wrong:

A: from multiplying instead of dividing.

B: that would be direct electric heating with no heat pump gain.

C: from taking away the electricity share wrongly.

The maths

Electricity = heat required / heat per kWh electricity
= 9,000 / 3
= 3,000 kWh a year

Memory trick:

Heat out divided by the ratio = electricity in.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 26

Reg AC 3.2 Heat pumps

Q2. What is a key requirement of the lake used for a water source heat pump?

Show answer

Answer: D. Big and deep enough that the pipes don't freeze

  • The lake must be close to the building.
  • It must be large and deep enough for a stable temperature so the pipes don't freeze.

Permission to use the water source is also needed.

Why the others are wrong:

A: shallow water risks freezing.

B: it must be close to the building.

C: no such requirement.

Memory trick:

Deep, close and allowed.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 29

Reg AC 3.2 Water source heat pumps

Q3. Which type of building is said to be unsuitable for an air source heat pump?

Show answer

Answer: B. A high-rise building

  • An ASHP needs only a suitable external wall, which almost all properties have.
  • The exception is high-rise buildings.

So it suits urban homes, unlike a GSHP.

Why the others are wrong:

A: these can be suitable, as only an external wall is needed.

C: suitable if it has an external wall.

D: ASHPs suit commercial buildings for heating or cooling.

Memory trick:

High rise, no ASHP prize.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 36

Reg AC 3.2 Air source heat pumps

Q4. Which benefit of using stored rainwater for the garden is given in the text?

Show answer

Answer: B. It is exempt from a summer hosepipe ban

  • Water from a storage vessel is exempt from a summer hosepipe ban.
  • It also avoids using metered, fluoridated mains water.

Plants prefer rainwater too.

Why the others are wrong:

A: not a benefit claimed.

C: the pump uses some electricity.

D: a large vessel is required.

Memory trick:

Your own rain, your own rules.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 37

Reg AC 3.2 Rainwater harvesting

Q5. The heat pump diagram shows 100% heat delivered to a building, with 25% coming from electrical energy. How much is free environmental energy?

Show answer

Answer: D. 75%

  • 75% free environmental energy + 25% electrical energy = 100% heat.
  • So every unit of electricity gives about four units of heat.

This is why heat pumps are efficient.

Why the others are wrong:

A: that is the electrical share.

B: the shares add up to 100%, not more.

C: the environmental share is three times the electrical share.

Memory trick:

Three parts free, one part paid.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 27

Reg AC 3.1 Heat pumps

Q6. What is meant by the 'balance point' of a heat pump?

Show answer

Answer: B. Where the heat pump's output meets the building's demand

  • The balance point is where the heat pump's output meets the building heat demand.
  • Below it, supplementary heat is needed.

Designing for 2 to 4 °C gives about 80% of total heating.

Why the others are wrong:

A: that is part of the refrigeration cycle.

C: not what the term means.

D: that is the payback point.

Memory trick:

Balance point: supply and demand shake hands.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 28

Reg AC 3.2 Air source heat pumps

Want 144 more QELTK3/002 questions? Start a free timed mock.