Q1. The Royal Commission of 1976 found a problem with tackling pollution one medium at a time. What was it?

Show answer

Answer: B. Cutting it in one medium raised it in another

  • Reducing a pollutant to one medium (air, water or land) led to an increase in another.
  • This is why an integrated approach to pollution control was stressed.

Integrated pollution control treats air, water and land together.

Why the others are wrong:

A: the finding was about pollution moving between media, not measurement.

C: no ranking of media was the issue.

D: the finding was technical, about transfer between air, water and land.

Memory trick:

Squeeze the balloon in one place and it bulges somewhere else.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 3

Reg Environmental Protection Act 1990

Q2. On site you have to shout to be heard by a colleague standing about 2 m away. What does this suggest?

Show answer

Answer: C. It is probably above 85 dB and should be measured

  • Rule of thumb: if you cannot hear someone 2 m away or they have to shout, the level is probably above 85 dB.
  • It should then be measured by a competent person.

This is a quick site check, not a measurement.

Why the others are wrong:

A: having to shout at 2 m points to a high level, not a low one.

B: shouting at 2 m does not indicate a peak impulse level.

D: the test indicates the noise level, not hearing damage.

Memory trick:

Shout at two metres, call the meter.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 5

Reg Control of Noise at Work Regulations

Q3. At the end of a job you have part coils of cable and spare lengths of trunking. What is the recommended re-use practice?

Show answer

Answer: C. Return them to stores and credit the job

  • Part coils and re-usable lengths go back to the employer's stores.
  • They are stored for future use and the returned quantities deducted from the job's costs.

Re-use sits above recycling in the hierarchy.

Why the others are wrong:

A: re-usable materials should not be skipped.

B: waste should not be left for someone else.

D: re-use is above recycling in the hierarchy.

Memory trick:

Back to stores, not to the skip.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 14

Reg AC 2.1 Re-use

Q4. A client plans a porch with a floor area of 2.8 m², 2.9 m high, sited 1.5 m from the boundary. Using the 2008 permitted development rules described, what applies?

Show answer

Answer: B. Planning is needed, as it is within 2 m of the boundary

  • Porch exemption: floor area no more than 3 m², height no more than 3 m, and more than 2 m from the boundary.
  • Area and height pass, but 1.5 m fails the boundary rule.

All three limits must be met.

Why the others are wrong:

A: it must also be more than 2 m from the boundary.

C: the area limit is 3 m².

D: the height limit is 3 m.

Memory trick:

Three, three, two: area, height, distance.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 33

Reg Permitted development

Q5. A contractor chooses factory-built modular wiring assemblies for a new office instead of making up all the wiring on site. What environmental benefit does the text give for this?

Show answer

Answer: B. Less fabrication on site, so less waste

  • Modular assemblies are assembled and tested at the factory.
  • There is less fabrication on site, which offers a means of waste reduction.

This fits the waste hierarchy aim of preventing waste in the first place.

Why the others are wrong:

A: modular assemblies are tested at the factory, but the installation must still be verified.

C: modular wiring still uses copper conductors.

D: any waste that is produced still needs proper transfer paperwork.

Memory trick:

Built in the factory, less waste on the floor.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 15

Reg Environmentally friendly procedures (text)

Q6. Under the Environmental Protection Act 1990, which principle is described as the cornerstone used by the Inspectorate when setting conditions to control pollution?

Show answer

Answer: A. Best practicable environmental option (BPEO)

  • The Inspectorate can set conditions to make sure the best practicable environmental option (BPEO) is used.
  • BPEO is described as the cornerstone of the Act.

Don't confuse it with BAT, which came in with the PPC Regulations 2000.

Why the others are wrong:

B: BAT was introduced later by the Pollution Prevention and Control regime.

C: that is a health and safety risk principle, not the EPA pollution test.

D: a general policy idea, not the cornerstone named in the Act.

Memory trick:

EPA = BPEO, PPC = BAT.

Find it in the book

Linsley, Electrical Installation Work Level 3 (EAL Edition), page 3

Reg Environmental Protection Act 1990

Want 144 more QELTK3/002 questions? Start a free timed mock.