Confined Spaces: Safe systems of work and permits practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

30 of our 120 Confined Spaces Awareness (CONFINED-SPACES) questions are on safe systems of work and permits, about 25% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. Why might L101 require a limit on the time individuals spend working in a confined space?

Show answer

Answer: B. RPE is worn, or conditions are extreme

  • L101: limit working time where RPE is used, under extreme temperature and humidity, or where the space is so small movement is severely restricted.
  • Time limits can be recorded on the permit-to-work.

Heat, heavy kit and cramped space all wear people down quickly.

Why the others are wrong:

A: L101 bases time limits on safety, not cost.

C: L101 sets no fixed permit expiry time.

D: L101 bases time limits on the conditions and equipment, not breaks.

Memory trick:

Hot, heavy or tight: limit the time.

Find it in the book

HSE L101 (3rd edition, 2014), page 32

Reg HSE L101 (3rd edition, 2014), para 136

Q2. Before a boiler or culvert is closed up again after work ('boxing-up'), what must the safe system make sure of?

Show answer

Answer: C. That everyone has left the space

  • L101: the safe system should ensure everyone has left during 'boxing-up'.
  • This matters most in complicated and extensive spaces with many entry and exit points.

A tally or logging system can help prove everyone is out.

Why the others are wrong:

A: the key check is that nobody is left inside.

B: the key check is that everyone has come out.

D: the key check is that everyone has come out.

Memory trick:

Count them out before you close up.

Find it in the book

HSE L101 (3rd edition, 2014), page 31

Reg HSE L101 (3rd edition, 2014), para 124

Q3. When may a petrol-driven pump be used inside a confined space?

Show answer

Answer: D. Never

  • L101: never use petrol-fuelled internal combustion engines in confined spaces, because of their fumes and how easily petrol vapour ignites.
  • INDG258: carbon monoxide in petrol engine exhaust is so dangerous that such equipment should never be allowed.

Diesel engines are nearly as hazardous and need exceptional precautions.

Why the others are wrong:

A: L101 says petrol engines should never be used in confined spaces.

B: ventilation does not make petrol engines acceptable.

C: there is no time limit that makes them acceptable.

Memory trick:

Petrol in a pit? Never permit.

Find it in the book

HSE L101 (3rd edition, 2014), page 30

Reg HSE L101 (3rd edition, 2014), para 118; HSE INDG258, 'Provision of ventilation'

Q4. A worker picked for a confined space job says he suffers from claustrophobia. What should happen?

Show answer

Answer: C. Assess his suitability, taking medical advice if needed

  • INDG258: the competent person may need to consider claustrophobia or fitness to wear breathing apparatus, and seek medical advice.
  • L101 also lists asthma and physical strength among suitability factors.

Unsuitable people can put themselves and others at risk.

Why the others are wrong:

A: claustrophobia is a factor INDG258 and L101 say should be considered.

B: his suitability must be assessed first, not managed by a quick fix.

D: a dust mask does nothing for claustrophobia and is not suitable RPE here.

Memory trick:

Fit for the space, fit for the job.

Find it in the book

HSE INDG258, page 4

Reg HSE INDG258, 'Are people suitable for the work?'; HSE L101, para 146

Q5. Where should a ventilation airline or trunking be placed in a vessel?

Show answer

Answer: A. At or extended to the bottom of the vessel

  • L101: an airline or trunking should be introduced at, or extend to, the bottom of the vessel.
  • This removes heavy gas or vapour and gives good air circulation, without hindering access or egress.

Extract air should go somewhere it cannot re-enter or create other risks.

Why the others are wrong:

B: L101 says it should reach the bottom to remove heavy gas or vapour.

C: it should be at or extended to the bottom.

D: it should be introduced at or extended to the bottom inside.

Memory trick:

Trunking to the bottom.

Find it in the book

HSE L101 (3rd edition, 2014), page 28

Reg HSE L101 (3rd edition, 2014), para 106

Q6. A large culvert has several entry points and many workers going in and out. What does L101 suggest?

Show answer

Answer: A. A logging or tally system to check people in and out

  • L101: for a large confined space and multiple entries, a logging or tally system may be needed.
  • It checks everyone in and out and controls duration of entry.

In an emergency, rescuers need to know who is still inside.

Why the others are wrong:

B: people need checking in and out throughout, not just at the end.

C: an informal approach will not reliably show who is still inside.

D: this would hamper escape and does not track who is inside.

Memory trick:

Tag in, tag out.

Find it in the book

HSE L101 (3rd edition, 2014), page 32

Reg HSE L101 (3rd edition, 2014), para 136

Want 114 more Confined Spaces questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other Confined Spaces topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic