Q1. Which description best matches a suitable rescuer according to INDG258?

Show answer

Answer: C. Trained, fit, close at hand and protected

  • INDG258: rescuers need to be properly trained, sufficiently fit, ready at hand, and capable of using rescue equipment.
  • They must also be protected against the cause of the emergency.

Multiple deaths happen when rescuers are overcome by the same conditions.

Why the others are wrong:

A: rescuers need to be properly trained, not just strong.

B: rescuers must be protected against the cause of the emergency.

D: rescuers need to be ready at hand.

Memory trick:

Trained, fit, near, protected.

Find it in the book

HSE INDG258, page 6

Reg HSE INDG258, 'Capabilities of rescuers'

Q2. What does L101 say about the system workers inside use to raise the alarm?

Show answer

Answer: B. It must be reliable and tested frequently

  • L101: the alarm can be raised by rope tug, radio or a 'lone worker' alarm.
  • Whatever the system, it should be reliable and tested frequently.

A dead radio is no alarm at all.

Why the others are wrong:

A: L101 says it should be tested frequently.

C: new equipment still needs frequent testing.

D: an alarm system is needed for every entry.

Memory trick:

Test the alarm, trust the alarm.

Find it in the book

HSE L101 (3rd edition, 2014), page 35

Reg HSE L101 (3rd edition, 2014), para 154

Q3. Can a contractor rely on dialling 999 as its rescue plan for confined space work?

Show answer

Answer: B. No, it must have its own arrangements

  • L101: you should not rely on the public emergency services.
  • Reliance on the emergency services alone will not be sufficient; employers must have arrangements in place before work starts.

Arrangements should still allow rapid notification of the emergency services.

Why the others are wrong:

A: L101 says you should not rely on the public emergency services.

C: reliance on emergency services alone is never enough, whatever the job length.

D: signal does not change the duty to have your own rescue arrangements.

Memory trick:

999 helps, but the plan is yours.

Find it in the book

HSE L101 (3rd edition, 2014), pages 34 to 37

Reg HSE L101 (3rd edition, 2014), paras 147 and 161

Q4. A worker wants to wear an escape breathing set to finish a quick task in a low-oxygen tank. Is this allowed?

Show answer

Answer: B. No, escape sets are only for getting out

  • L101: escape sets or 'self-rescuers' are only used for emergency escape and not for working applications.
  • They are not a substitute for RPE.

They give a short time to reach a place of safety.

Why the others are wrong:

A: escape sets are only for emergency escape, not for working.

C: supervision does not make an escape set suitable for work.

D: a harness does not change what an escape set is for.

Memory trick:

Escape set: for getting out, not getting on.

Find it in the book

HSE L101 (3rd edition, 2014), page 40

Reg HSE L101 (3rd edition, 2014), paras 150 and 176

Q5. A worker in a dry, tested chamber trips and breaks an ankle, and cannot climb out. Must the reg 5 rescue arrangements cover this?

Show answer

Answer: C. Yes, they cover any emergency needing recovery

  • Reg 5(1): arrangements are needed for rescue in an emergency whether or not arising out of a specified risk.
  • L101 gives incapacitation following a fall as an example.

Getting an injured person out of a manhole needs planning and equipment.

Why the others are wrong:

A: reg 5 applies whether or not the emergency arises from a specified risk.

B: L101 gives incapacitation after a fall as an example to plan for.

D: the arrangements must cover the fall whatever caused it.

Memory trick:

Any emergency, same duty.

Find it in the book

HSE L101 (3rd edition, 2014), page 34

Reg Confined Spaces Regulations 1997, reg 5(1) (HSE L101, para 147)

Q6. Where should the free end of a lifeline attached to a rescue harness be secured?

Show answer

Answer: A. At a point outside the confined space

  • INDG258: lifelines attached to harnesses should run back to a point outside the confined space.
  • L101: the free end must be secured so it can be used as part of the rescue procedure.

Lifting equipment may be needed to draw the person out.

Why the others are wrong:

B: the line must be usable by others outside for rescue.

C: the line should run back to a point outside.

D: the line must be secured outside so it can be used in a rescue.

Memory trick:

Lifeline end stays outside.

Find it in the book

HSE INDG258, page 5

Reg HSE INDG258, 'Provision of rescue harnesses'; HSE L101, para 178

Want 114 more Confined Spaces questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other Confined Spaces topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic