Fire Marshal: Evacuation, alarms and the fire marshal's role practice questions

Written by Acacio Oliveira, founder of FreeMocks, plumbing and heating engineer (F-Gas registered).

30 of our 120 Fire Marshal (Fire Warden) Training (FIRE-MARSHAL) questions are on evacuation, alarms and the fire marshal's role, about 25% of the bank. Try 6 below with full worked answers, then practise the rest in a timed mock.

Practice questions

Pick an answer to see why it's right, why the others are wrong, and the page in the book.

Q1. A wheelchair user is waiting in a refuge on the stairway during an evacuation. What does the guide say?

Show answer

Answer: B. They should not be left alone while waiting for help

  • A refuge is a place of reasonable safety where disabled people can wait for an evacuation lift or help on the stairs.
  • Disabled people should not be left alone in a refuge, and the plan should not rely on the fire and rescue service to rescue them.

Refuges must only be used with effective management rescue arrangements.

Why the others are wrong:

A: the strategy should not rely on the fire and rescue service rescuing people in refuges.

C: a refuge is a protected place; going back onto the floor is not.

D: normal lifts are only used where assessed and designated for evacuation.

Memory trick:

Never leave anyone alone in a refuge.

Find it in the book

GOV.UK Fire safety risk assessment: offices and shops (2006), page 65

Reg GOV.UK Fire safety risk assessment: offices and shops, Part 2, Section 4.1: Mobility impairment (refuges)

Q2. An electrical fire-warning system needs a back-up power supply. What should the back-up normally be able to do?

Show answer

Answer: D. Run the system for 24 hours, then sound the alarm for 30 minutes

  • The Health and Safety (Safety Signs and Signals) Regulations 1996 require a necessary electrical fire-warning system to have a back-up power supply.
  • It should normally operate the system for at least 24 hours and sound the alarm in all areas for 30 minutes.

If you are unsure whether your existing system is adequate, consult a competent person.

Why the others are wrong:

A: 3 hours is the most popular emergency lighting duration, not the alarm back-up.

B: the monitoring time is far too short and the sounding time far too long.

C: the figures are wrong; it is 24 hours of operation and 30 minutes of alarm.

Memory trick:

24 hours watching, 30 minutes shouting.

Find it in the book

GOV.UK Fire safety risk assessment: offices and shops (2006), page 56

Reg GOV.UK Fire safety risk assessment: offices and shops, Part 2, Section 2.6: Guaranteed power supply

Q3. After everyone has evacuated, when should the roll call be carried out?

Show answer

Answer: B. As soon as possible at the designated assembly point

  • Carry out a roll call as soon as possible at the designated assembly point(s), and/or take reports from wardens who sweep the premises.
  • Note anyone unaccounted for; in a real fire this is passed to the fire and rescue service on arrival.

In a drill, people return only once the roll call or reports are complete.

Why the others are wrong:

A: people unaccounted for must be identified straight away.

C: the information is needed by the fire service on arrival, not afterwards.

D: people should stay at the assembly point, not go back in to be counted.

Memory trick:

Count heads at the assembly point.

Find it in the book

GOV.UK Fire safety risk assessment: offices and shops (2006), page 112

Reg GOV.UK Fire safety risk assessment: offices and shops, Part 2, Section 7.4: The roll call

Q4. In normal-risk premises, roughly how many people can an escape route with a width of at least 750mm accommodate?

Show answer

Answer: B. Up to 100 people

  • 750mm: up to 80 (higher risk), 100 (normal), 120 (lower).
  • 1050mm: up to 160, 200 or 240; allow an extra 75mm for each additional 15 people.

Measure the width at the narrowest point, usually a door.

Why the others are wrong:

A: 80 is the figure for higher-risk premises.

C: 120 is the figure for lower-risk premises.

D: 200 is for a width of at least 1050mm in normal risk.

Memory trick:

Seven-fifty for a hundred.

Find it in the book

GOV.UK Fire safety risk assessment: offices and shops (2006), page 67

Reg GOV.UK Fire safety risk assessment: offices and shops, Part 2, Section 4.1: Widths and capacity of escape routes

Q5. A disabled employee regularly works in your building. What does the guide suggest you develop with them for evacuation?

Show answer

Answer: B. A personal emergency evacuation plan (PEEP)

  • You may need to develop individual personal emergency evacuation plans (PEEPs) for disabled people who frequently use a building.
  • Discuss their needs with them so they are confident in the plan, and consider personal dignity.

For members of the public, a range of standard PEEPs can be provided on request.

Why the others are wrong:

A: PPE registers are not about escaping from fire.

C: permits to work control high-risk jobs such as hot work, not evacuation.

D: phased evacuation is a building-wide strategy, not an individual plan.

Memory trick:

PEEP: a personal plan, made with the person.

Find it in the book

GOV.UK Fire safety risk assessment: offices and shops (2006), page 52

Reg GOV.UK Fire safety risk assessment: offices and shops, Part 2, Section 1.13: Help for people with special needs

Q6. A large store uses a staged fire alarm. When should disabled people be alerted?

Show answer

Answer: B. On the first stage, to give them the most time to escape

  • Staged alarms give an alert signal and a different evacuate signal.
  • Where staged alarms are used, disabled people should be alerted on the first stage to give them the maximum time to escape.

Where the first alert goes to certain staff, those staff must be fully trained and available at all times.

Why the others are wrong:

A: waiting for the evacuate signal loses valuable time.

C: they should not wait for the fire service.

D: they should be alerted on the first stage wherever they are.

Memory trick:

Slower to move? First to know.

Find it in the book

GOV.UK Fire safety risk assessment: offices and shops (2006), page 55

Reg GOV.UK Fire safety risk assessment: offices and shops, Part 2, Section 2.4: Staged fire alarms

Want 114 more Fire Marshal questions? Start a free timed mock.

Start a free mock

Full mock, no card needed. Full workouts on the first 5 questions.

Other Fire Marshal topics

Free official guides for this topic

Our questions are written from these documents. Download them free to revise from the source.

© Crown copyright (GOV.UK, HSE). Unchanged copies, reproduced under the Open Government Licence v3.0. FreeMocks is not connected to or endorsed by HSE or the government.

Revise this topic